Thứ Ba, 23 tháng 6, 2015

Hi-Q – THIẾT BỊ LẤY MẪU BỤI PM10 THỂ TÍCH LỚN VỚI ĐIỀU KHIỂN LƯU LƯỢNG BẰNG TAY hoặc TỰ ĐỘNG Hi – Q PM10-Series Model: PM10-Series

Hi-Q – THIẾT BỊ LẤY MẪU BỤI PM10 THỂ TÍCH LỚN VỚI ĐIỀU KHIỂN LƯU LƯỢNG BẰNG TAY hoặc TỰ ĐỘNG Hi – Q PM10-Series
Model: PM10-Series
Hãng sản xuất: Hi – Q – Mỹ

Tính năng kỹ thuật THIẾT BỊ LẤY MẪU BỤI PM10 THỂ TÍCH LỚN VỚI ĐIỀU KHIỂN LƯU LƯỢNG BẰNG TAY hoặc TỰ ĐỘNG Hi – Q PM10-Series:
-          Complete Systems Designed to Meet or  Exceed U.S. EPA Federal Reference Method Performance Specifications for PM-10 Sampling
-           Seven          High  Performance  Systems to choose from
-          Brushless & Brushed Motor Driven 2 & 3-Stage Blowers         Available
-           NIST Traceable Flow Calibration

Thông số kỹ thuật THIẾT BỊ LẤY MẪU BỤI PM10 THỂ TÍCH LỚN VỚI ĐIỀU KHIỂN LƯU LƯỢNG BẰNG TAY hoặc TỰ ĐỘNG Hi – Q PM10-Series:
-          Motor/Pump: 
PM10-5300AFC: Brushless, Electronic Control/3-Stage.
PM10-5200AFC: Brushless, Electronic Control/2-Stage.
PM10-4300AFC: Brushless, Electronic Control/3-Stage.
PM10-4200AFC: Brushless, Electronic Control/2-Stage.
PM10-3300BRL: Brushless, Mechanical Control/3-Stage.
PM10-3000BRL: Brushless, Mechanical Control/2 Stage.
PM10-2000: Brushed, Mechanical Control/2-Stage.

-          Housing:  Anodized Aluminum Outdoor Shelter with lockable control panel door. See HI-Q’s HVP-2000 & PM10-HEAD for overall cabinet & Size Selective Inlet dimensions.
-          Calibrated Flow Range:  10-50 CFM (CMM unit calibration upon request). NISTTraceable Calibration.
-          Unit Net Weight:  ~50 lbs. Cabinet Weight (avg.). 44 lbs. Size Selective Inlet.
-          Shipping Weight & Dimensions:   
20” x 20” x 50” @ 58 lbs. Cabinet Carton (avg.).
32” x 32” x 26” @ 52 lbs. Size Selective Inlet Carton.

-          PM10-3-Stage Power Specifications: 
115 VAC, 50/60 Hz.,10 Amp, 800 Watt
230 VAC, 50/60 Hz., 10.5 Amp, 1200 Watt

-          PM10-2-Stage  Power Specifications: 
115 VAC, 50/60Hz., 5.0 Amp, 250 Watt
230 VAC, 50/60Hz., 5.0 Amp, 400 Watt

-          PM10-2000 Power Specifications: 
115 VAC, 50/60Hz., 9.0 Amp, 300 Air Watts
230 VAC, 50/60Hz., 4.6 Amp, 269 Air Watts

-          Elapsed Timer:  Electronic, Resettable Hours & Tenths of Hours, (all units)  LCD read out, 5 year internal battery.
-          Flow Totalizer: (PM10-5300, Resettable Standard Cubic Feet 5200, 4300 & 4200 only)  (total volume in cubic meters or liters upon request)
-          Flow Display: (PM10-5300,  Standard Cubic Feet per Minute 5200, 4300 & 4200 only)  (SCCM or SLPM display upon request)
-          Flow Calibrator:  See Air Flow Calibrators
-          Filter Media:  See Filter Media For Air Sampling Section
-          Optional Equipment:  See “Options” listed above & Air Sampling Accessories

Thông tin đặt hàng THIẾT BỊ LẤY MẪU BỤI PM10 THỂ TÍCH LỚN VỚI ĐIỀU KHIỂN LƯU LƯỢNG BẰNG TAY hoặc TỰ ĐỘNG Hi – Q PM10-Series:


Model
Mô tả
PM10-5300AFC (3-Stage) & PM10-5200AFC (2-Stage)
Automatic/PID Mass Flow Control, PM10 HI-Vol Air Sampling System, 115 VAC, with PLC controlled 3 or 2 Stage Brushless Blower. Date logs to Micro-SD Card in .csv format. Unit includes 8” x 10” filter paper holder, 8”
x 10” paper cartridge and PM-10 Size Selective Inlet. Standard Units are
SCFM. See HVP-5300/5200AFC Series samplers for complete description
& available options.
PM10-4300AFC (3-Stage) & PM10-4200AFC (2-Stage)
Automatic/PID Mass Flow Control, PM-10 HI-Vol Air Sampling System, 115
VAC, with PLC controlled 3 or 2 Stage Brushless Blower. Unit includes 8”
x 10” filter paper holder, 8” x 10” paper cartridge and PM-10 Size Selective
Inlet. Standard Units are SCFM. See HVP-4300/4200AFC Series samplers
for complete description & available options.
PM10-3300BRL (3-Stage) & PM10-3000BRL (2-Stage)
Manual Speed Control, Brushless 3 or 2 Stage Blower, PM-10, High Vol
Air Sampling System. 115VAC. Unit includes 8”x10” filter paper holder, 8”
x 10” paper cartridge and PM-10 Size Selective Inlet. Standard Units are
ACFM. See HVP-3300/3000BRL Series samplers for complete description
& available options.
PM10-2000
Manual Speed Control, Brushed Motor Blower PM-10, HI-Vol Air Sampling
System. 115 VAC. Unit includes 8” x 10” filter paper holder, 8” x 10” paper
cartridge and PM-10 Size Selective Inlet. Standard Units are ACFM. See
HVP-2000 Series samplers for complete description & available options.
PM10-5300AFC/230,PM10-5200AFC/230,PM10-4300AFC/230, PM10-4200AFC/230,PM10-3300BRL/230, PM10-3000BRL/230, & PM10-2000/230 are
the 230 Volt versions of units described above.
LỰA CHỌN THÊM:
-          7DAYTMR: Mechanical 7 Day Skip Timers
-          7DAY-ELCTMR: Programmable Electronic Timer
-          HVP-PR4-3: Continuous Flow/Pressure Recorder
-          HVP-CAB-STBLZRS: Cabinet Stabilizer Set
-          EXHAST-10: 10’ Exhaust Tubing
-          HIQ-6009: Silicone Release Spray for shim plate
-          810-CARTRIDGE: Additional 8”x10”: paper cartridge