FLUKE
– Máy đo điện trở đất Fluke 1621
Model:
Fluke 1621 GEO
Hãng
sản xuất: FLUKE – MỸ
Tính năng Máy đo điện trở đất Fluke 1621:
- 3-pole Fall-of-Potential earth testing for basic
measurements
- 2-pole resistance measurements for added
versatility
- Easily capture values with single-button
operation
- Ensure accurate measurements with automatic
‘noise’ voltage detection
- Hazardous voltage warning offers increased user
protection
- Clearly read and record data with a large,
backlit display
- Rugged holster and design for tough work environments
- Portable size allows for easy transportation
- Instantly be alerted to measurements outside of
your set limit, when you use the adjustable limit setting
- 600 V Cat II
Thông số kỹ thuật Máy đo điện trở đất Fluke 1621:
General specifications
|
Measuring functions
|
|
3-pole earth ground resistance, 2-pole ac resistance of a
conductor, Interference voltage
|
|
Intrinsic error
|
|
Refers to the reference temperature range and is guaranteed for
one year
|
|
Measuring rate
|
|
Battery[1]
|
|
One 9 volt alkaline (LR61)
|
|
Battery condition
|
|
LO-BAT is displayed if voltage drops below 6.5 V
|
|
Voltages
|
Between jacks H/C2 and E/C1:
|
250 Veff maximum (effective voltage)
|
Between jacks S/P2 and E/C1:
|
250 Veff maximum
|
|
Climatic class
|
|
VDE/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4/87)
|
|
Temperature performance[2]
|
Working:
|
-10 °C to +50 °C (+14 °F to +122 °F)
|
Operating:
|
0 °C to +35 °C (+32 °F to +95 °F)
|
Storage:
|
-20 °C to +60 °C (+68 °F to +140 °F)
|
Reference:
|
+23 °C ± 2 °C (+73 °F ± 4 °F)
|
|
Temperature coefficient
|
|
± 0.1 % of range per degree Kelvin
|
|
Safety
|
|
IEC/EN 61010-1, 600 V CAT II, pollution degree 2
|
|
Dimensions
|
|
113 mm x 54 mm x 216 mm (4.5 in x 2.1 in x 8.5 in), including
holster
|
|
Weight
|
|
850 g (1.9 lb), including standard accessories, volume
approximately 600 cm3
|
|
Note:
|
|
[1]If the tester is not going to be used, or is being stored for
a long period, remove the battery and store separately from the tester to
avoid damage from battery leakage.
|
|
Note:
|
|
[2]The four temperature ranges for the tester exists to satisfy
European Standards requirements; the instrument can be used over the full
working temperature range by using the temperature coefficient to calculate
accuracy at the ambient temperature of use.
|
|
Electrical specifications
|
Maximum deviations:
|
E1 Influence factor
|
Position
|
E1 Deviation influence
|
0 %
|
E2 Influence factor
|
Supply voltage
|
E2 Deviation influence
|
0 %
|
E3 Influence factor
|
Temperature E3
|
E3 Deviation influence
|
2.3 %
|
E4 Influence factor
|
Serial interference voltage (20 V)
|
E4 Deviation influence
|
0.6 %
|
E5 Influence factor
|
Probe- and auxiliary probe resistance
|
E5 Deviation influence
|
10 %
|
|
Test voltage
|
|
Protection type
|
|
Electromagnetic compatibility
|
|
Emission: IEC/EN 61326 Class B
|
|
Immunity: IEC/EN 61326 Annex C
|
|
RE resistance measurement
|
Measuring method
|
Current-voltage measurement with improved cross-talk attenuation,
no compensation of measuring lead resistance, with probe (3-pole) or
without probe (2-pole), as per IEC/EN 61557-5
|
Open circuit voltage
|
23 to 24 V ac
|
Short circuit current
|
> 50 mA ac
|
Measuring frequency
|
128 Hz
|
Maximum permissible overload
|
250 Veff
|
|
Measuring time
|
|
8 seconds (average from when START is pressed)
|
|
Limit input
|
|
Tester retains set value even if instrument is turned off
(assuming battery power supply is sufficient)
|
|
Automatic changeover of resolution
|
RH
|
< 7 kΩ
|
Resolution
|
0.01 Ω
|
RH
|
< 50 kΩ
|
Resolution
|
0.1 Ω
|
RH
|
> 50 kΩ
|
Resolution
|
1 Ω
|
|
Interference voltage display dc + ac
|
Vmax
|
30 Veff
|
Common mode rejection
|
> 80 dB at 50 Hz and 60 Hz
|
Ri
|
680 kΩ
|
Measuring uncertainty
|
< 10 % for pure ac and dc signals
|
|
Measuring range
|
0.15 Ω to 20 Ω
|
Resolution
|
0.01 Ω
|
Display range
|
0 to 19.99 Ω
|
|
200 Ω
|
Resolution
|
0.1 Ω
|
Display range
|
20 to 199.9 Ω
|
|
2 kΩ
|
Resolution
|
1 Ω
|
Display range
|
200 to 1999 Ω
|
|
Intrinsic uncertainty
|
|
± (6 % of measured value + 5D)
|
|
Operating uncertainty IEC 61557[1]
|
|
± (18 % of measured value + 5D)
|
|
Notes:
|
|
[1] Covers all deviations caused by influence quantities E1-E5.
If the deviation E4 caused by high probe or auxiliary probe resistance is higher than
specified flashes.
Measured values are outside of the specified operating uncertainty.
|
|