FLUKE – Thiết bị đo công suất 3 pha có ghi lại Fluke 1730 Model: Fluke 1730

FLUKE – Thiết bị đo công suất 3 pha có ghi lại Fluke 1730
Model: Fluke 1730
Hãng sản xuất: FLUKE – MỸ
                                Kết quả hình ảnh cho Fluke 1730  FLUKE
Tính năng Thiết bị đo công suất 3 pha có ghi lại Fluke-1730:

  • Key measurements: Voltage, current, power, power factor and associated values enable you to optimize and implement your energy saving strategies.
  • Bright, color touch screen: Perform convenient in-the-field analysis and data checks with full graphical display.
  • Comprehensive logging: More than 20 separate logging sessions can be stored on the instrument. In fact, all measured values are automatically logged and can be reviewed during logging and before downloading for on-the-go analysis.
  • Optimized user interface: Capture the right data every time with quick, guided, graphical setup and reduce uncertainty about your connections with the intelligent verification function.
  • Complete "in-the-field" setup through the front panel: no need to return to the workshop for download and setup or to take a computer to the electrical panel.
  • Wide range power: power instrument directly from the measured circuit eliminating the need to find a power outlet while allowing the instrument to be secured safely inside electrical panels.
  • Two USB ports: one for PC connection and another for fast, simple download to standard USB thumb drives, or other USB devices.
  • Compact size: designed to fit in tight spaces and panels.
  • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream.
  • Optimized measurement accessories: flat voltage cable and thin flexible current probes ensure easy installation even in tight spaces.
  • Battery life: four-hour operating time (backup time) per charge on lithium-ion battery.
  • Security: We safeguard your best asset from theft with a hefty, durable Kensington lock.
  • Energy analyze application software: Download and analyze a snapshot of your energy savings potential with our automated reporting.

Thông số kỹ thuật Thiết bị đo công suất 3 pha có ghi lại Fluke-1730:
Specifications
Accuracy
Parameter
Range
Resolution
Intrinsic Accuracy at Reference Conditions (% of Reading + % of Full Scale)
Voltage
1000 V
0.1 V
± (0.2 % + 0.01 %)
Current: Direct input
iFlex1500-12
150 A
0.1 A
± (1 % + 0.02 %)
1500 A
1 A
iFlex3000-24
300 A
1 A
± (1 % + 0.02 %)
3000 A
10 A
iFlex6000-36
600 A
1 A
± (1.5 % + 0.03 %)
6000 A
10 A
i40s-EL clamp
4 A
1 mA
± (0.7 % + 0.02 %)
40 A
10 mA
Frequency
42.5 Hz to 69 Hz
0.01 Hz
± (0.1 %)
Auxillary input
± 10 V dc
0.1 mV
± (0.2 % + 0.02 %)
Voltage min/max
1000 V
0.1 V
± (1 % + 0.1 %)
Current min/max
defined by accessory
defined by accessory
± (5 % + 0.2 %)
Cosφ/DPF
0 <= Cosφ <=1
0.01
± 0.025
Power factor
0 <= PF <=1
0.01
± 0.025
THD on voltage
1000 %
0.1 %
± (2.5 % ± 0.05)
THD on current
1000 %
0.1 %
± (2.5 % ± 0.05)

Intrinsic Uncertainty ± (% of reading + % of range)1
Parameter
Influence quantity
iFlex1500-12
iFlex3000-24
iFlex6000-36
i40S-EL
150A/1500A
300A/3000A
600/6000A
4A/40A
Active power P
PF ≥ 0.99
1.2 % + 0.005 %
1.2 % + 0.0075 %
1.7 % + 0.0075 %
1.2 % + 0.005 %
0.5 < PF < 0.99
1.2 % + 7 x (1-PF) +0.005 %
1.2 % + 7 x (1-PF) + 0.0075 %
1.7 % + 7 x (1-PF) + 0.0075 %
1.2 % + 10 x (1-PF) + 0.005 %
Apparent power S, S fund.
0 ≤ PF ≤ 1
1.2 % + 0.005 %
1.2 % + 0.0075 %
1.7 % + 0.0075 %
1.2 % + 0.005%
Reactive power N, Q fund.
0 ≤ PF ≤ 1
2.5 % of measured apparent power
Additional uncertainty in % of range1
U >250 V
0.015 %
0.0225 %
0.0225 %
0.015 %
1Range = 1000 V x Irange
Reference conditions: 
Environmental: 23 °C ± 5 °C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH <65 % 
Input conditions: Cosφ/PF=1, Sinusoidal signal f=50 Hz/60 Hz, power supply 120 V/230 V ±10 %
Current and power specifications: Input voltage 1 ph: 120 V/230 V or 3 ph wye/delta: 230 V/400 V 
Input current: I > 10 % of Irange 
Primary conductor of clamps or Rogowski coil in center position 
Temperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C

Electrical Specifications
Power Supply
Voltage range
100 V to 500 V using safety plug input when powering from the measurement circuit
100 V to 240 V using standard power cord (IEC 60320 C7)
Power consumption
Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
Efficiency
≥ 68.2 % (in accordance with energy efficiency regulations)
Maximum no-load consumption
< 0.3 W only when powered using IEC 60320 input
Mains power frequency
50/60 Hz ± 15 %
Battery
Li-ion 3.7 V, 9.25 Wh, customer-replaceable
On-battery runtime
Four hours in standard operating mode, up to 5.5 hours in power saving mode
Charging time
< 6 hours
Data Acquisition
Resolution
16-bit synchronous sampling
Sampling frequency
5120 Hz
Input signal frequency
50/60 Hz (42.5 to 69 Hz)
Circuit types
1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye, 3-φ wye IT, 3-φ wye balanced, 3-φ 
Aron/Blondel (2-element delta), 3-
φ delta open leg, Currents only (load studies)
THD
THD for voltage and current is calculated using 25 harmonics
Averaging period
User selectable
1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
Demand interval
User selectable
5 min, 10 min, 15 min, 20 min, 30 min
Data storage
Internal flash memory (not user replaceable)
Memory size
Typical 20 logging sessions of 10 weeks with 10-minute intervals¹
Logging period
Averaging period
Recommended
20 sessions
1 session
1 second
3 hours
2.5 days
5 seconds
15 hours
12 days
10 seconds
28 hours
24 days
30 seconds
3.5 days
10 weeks
1 minute
7 days
20 weeks
5 minutes
5 weeks
2 years
10 minutes
10 weeks
> 2 years
15 minutes
3.5 months
> 2 years
30 minutes
7 months
> 2 years¹
Interfaces
USB-A
File transfer via USB flash drive, firmware updates 
Max. current: 120 mA
USB-mini
Data download device to PC
Extension port
Accessories
Voltage Inputs
Number of inputs
4 (3 phases and neutral)
Maximum input voltage
1000 Vrms, CF 1.7
Input impedance
10 MΩ
Bandwidth (-3 dB)
2.5 kHz
Scaling
1:1, 10:1, 100:1, 1000:1 and variable
Measurement category
1000 V CAT III/600 V CAT IV
Current Inputs
Number of inputs
3, mode selected automatically for attached sensor
Input voltage
Clamp input: 500 mVrms/50 mVrms; CF 2.8
Rogowski coil input
150 mVrms / 15 mVrms at 50 Hz, 180 mVrms / 18 mVrms at 60 Hz; CF 4; all at nominal probe range
Range
1 A to 150 A/10 A to 1500 A with thin iFlex flexible current probe, 12 inches
3 A to 300 A/30 A to 3000 A with thin iFlex flexible current probe, 24 inches
6 A to 600 A/60 A to 6000 A with thin iFlex flexible current probe, 36 inches
40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL
Bandwidth (-3 dB)
1.5 kHz
Scaling
1:1 and variable
Auxiliary Inputs
Number of inputs
2
Input range
0 to ± 10 V dc, 1reading/s
Scale factor (available 2014)
Format: kx + d user configurable
Displayed units (available 2014)
User configurable (7 characters, for example, °C, psi, or m/s)
1.    The number of possible logging sessions and logging period depends on user requirements.

Environmental Specifications
Operating temperature
-10 °C to +50 °C (14 °F to 122 °F)
Storage temperature
-20 °C to +60 °C (4 °F to 140 °F)
Operating humidity
10 °C to 30 °C (50 °F to 86 °F) max. 95 % RH
30 °C to 40 °C (86 °F to 104 °F) max. 75 % RH
40 °C to 50 °C (104 °F to 122 °F) max. 45 % RH
Operating altitude
2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
Storage altitude
12,000m
Enclosure
IP50 in accordance with EN60529
Vibration
MIL 28800E, Type 3, Class III, Style B
Safety
IEC 61010-1: Overvoltage CAT IV, Measurement 1000 V CAT III / 600 V CAT IV, Pollution Degree 2
EMI, RFI, EMC
EN 61326-1: Industrial
Electromagnetic compatibility
Applies to use in Korea only. Class A equipment (industrial broadcasting and communication equipment)
Radio frequency emissions
IEC CISPR 11: Group 1, Class A
Temperature coefficient
0.1 x accuracy specification/°C

General Specifications
Color LCD display
4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel
Warranty
1730 and power supply
Two-years (battery not included)
Accessories
One-year
Calibration cycle
Two-years
Dimensions
1730
19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in)
Power supply
13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in)
1730 with power supply attached
19.8 cm x 16.7 cm x 9 cm 
(7.8 in x 6.6 in x 3.5 in)
Weight
1730
1.1 kg (2.5 lb)
Power supply
400 g (0.9 lb)
External protection
Holster, Kensington lock slot
1500-12 iFlex Flexible Current Probe

Specifications
Measuring range
1 to 150 A ac / 10 to 1500 A ac
Nondestructive current
100 kA (50/60 Hz)
Intrinsic error at reference condition*
± 0.7 % of reading
Accuracy 1730 + iFlex
± (1 % of reading + 0.02 % of range)
Temperature coefficient over operating temperature range
0.05 % of reading/°C 0.09 % of reading/°F
Working voltage
1000 V CAT III, 600 V CAT IV
Probe cable length
305 mm (12 in)
Probe cable diameter
7.5 mm (0.3 in)
Minimum bending radius
38 mm (1.5 in)
Output cable length
2 m (6.6 ft)
Weight
115 g
Transducer cable material
TPR
Coupling material
POM + ABS/PC
Output cable
TPR/PVC
Operating temperature
-20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176°F)
Temperature, non-operating
-40 °C to +80 °C (-40 °F to 176 °F)
Relative humidity, operating
15 % to 85 % non-condensing
IP rating
IEC 60529:IP50
Warranty
One-year
*Reference condition:
  • Environmental: 23 °C ± 5 °C, no external electrical/magnetic field, RH 65 %
  • Primary conductor in center position