Thiết bị kiểm tra độ chống nổ
thủy lực lốp xe
Model:
HZ-7030
Equipment
characteristics:
-
The core pressurization equipment
selection of Shandong Province produced booster pump can be easily output
pressure is adjustable, controllable.
-
Advanced technology, reasonable
structure design. With small size, light weight and generous appearance.
-
All pressure parts are a standard
part of the internationally renowned brand, no welded connections for easy
removal, high safety factor, long life, easy to maintain.
-
Drive air pressure :0.1-0 .8Mpa;
proportional to the output pressure and driving pressure.
-
Air consumption: 0.6-1Nm3/min
-
Stress test range:0—60Mpa, (based
on actual customer demand, corresponding to the pressure.)
Product
performance parameters:
-
Pressure trial medium: water
-
Test pressure: Liquid up to 600
kg, arbitrary adjustable within this range can be achieved by regulating the
compressed air drive pressure pressure regulation changes, different booster
pump corresponding to the different pressure.
-
Data show: Accuracy:1Mpa
-
Pressure control: By controlling
the drive gas pressure, the value of the low-end gas pressure can be high-end
liquid pressure adjustment
-
Drive pressure range:
0.2Mpa-0.8Mpa,Air
consumption 0.6-1 Cubic meters / minute
-
Specimen installation: Manual
-
Pressure sampling frequency:
1times/s
-
Alarm: You can set the alarm
value, alarm set. And control system to shut down suppress. Into the packing
state
Technical
parameters:
-
Model: HZ-7030 Tire-resistant
hydraulic burst test machine
-
Basic principles: Tire pressure,
high-pressure pump high-pressure liquid pressure control system, transported by
the high pressure hose to the sample, the tires for a long time hydrostatic
testing and blasting. Record rupture pressure values.
-
Performance parameters:
§ International
standard: ISO 6803; ISO6772; ISO6802; SAEJ343
§ Domestic
standard :GB/T3683;GB/T7939;GB/T5568
§ Test
pressure: 0~60MPa
§ Controlling
pressure acuracy: upper limit value of +2%, lower limit of -1%
§ Test
medium: water
§ Pressure
control mode: Pressure-driven or hydraulic drive
§ Mode
of operation: Manual control
§ Number
of samples: Road 1 control test pressure and test time
§ Temperature
accuracy: difference:±10,max deviation:±20
§ Sample
installation method: manual clamping
-
Structure and composition: Power
system, circulatory system, the pressure control system, the workpiece device,
manual control
Scope
of application: Tire and tube
Không có nhận xét nào: