FLUKE
- Ampe kìm Fluke 307/309 (Fluke 317/319 Clamp Meters)
Model:
Fluke 307/309
Hãng
sản xuất: FLUKE – MỸ
Tính năng Ampe kìm Fluke 307/309:
The two models are economic, compact and offer a range of special features:
- Unique 40A high-precision low current
measurement--0.01A high-resolution, 1.6% high-precision
measurement"
- The clamps are slim, lightweight, and portable,
making them ideal for use in small, confined spaces"
- The large backlight display facilitates
readings in dark environments"
- Starting current (inrush) functionality (319)
allows measurement of the starting current of electrical and lighting
equipment, for example. (319)
- Current frequency measurement
- Precision down to 0.01A and 0.1V
- 1000A/600A AC/DC current measurement (319/317)
- 600V AC/DC voltage measurement
- 4000Ω resistance measurement
- Continuity beeper
- Auto off function enhances battery life,
meaning the instrument can work when you need it screen store ‘hold’
function for capturing a measurement result on the screen
- One year warranty
Thông số kỹ thuật Ampe kìm Fluke 307/309:
General Specifications
|
Digital Display
|
|
Low Battery Indication
|
|
Displays a signal when the batteries are below their required
voltage
|
|
Power Source
|
|
Three AAA IEC LR03 batteries
|
|
Jaw opening
|
|
Jaw opening
|
|
Dimensions (L x W x H)
|
|
Weight
|
|
approximately 13.5 oz (384 g) (batteries included)
|
|
Automated measurement
|
|
Safety
|
|
CE
|
|
EN/IEC 61010-1 and IEC 61010-2-032
|
|
Installation
type III, 600V working
environment
|
|
317 Electrical Specifications
|
Current AC
|
Range
|
40.00 A, 600.0 A
|
Resolution
|
0.01 A, 0.1 A
|
Accuracy
|
1.6% ± 6 digit (50-60 Hz) {40 A}
|
|
2.5% ± 8 digit (60-500 Hz) {40 A}
|
|
1.5% ± 5 digit (50-60 Hz) {600 A}
|
|
2.5% ± 5 digit (60-500 Hz) {600 A}
|
Crest Factor add 2% into spec for CF > 2
|
3.0 Max @ 500 A, 2.5 Max @ 600 A
|
AC response
|
rms
|
|
Current DC
|
Range
|
40.00 A, 600.0 A
|
Resolution
|
0.01 A, 0.1 A
|
Accuracy
|
1.6% ± 6 digit (40 A)
|
|
1.5% ± 5 digit (600 A)
|
|
Voltage AC
|
Range
|
600.0 V
|
Resolution
|
0.1 V
|
Accuracy
|
1.5% ± 5 digit (20-500Hz)
|
AC response
|
rms
|
|
Voltage DC
|
Range
|
600.0 V
|
Resolution
|
0.1 V
|
Accuracy
|
1% ± 4 digit
|
|
Resistance
|
Range
|
400.0 Ω, 4000 Ω
|
Resolution
|
0.1 Ω, 1 Ω
|
Accuracy
|
1% ± 5 digit
|
|
Continuity
|
|
Inrush
|
|
Frequency
|
Range
|
N/A
|
Accuracy
|
N/A
|
Trigger Level
|
N/A
|
|
319 Electrical Specifications
|
Current AC
|
Range
|
40.00 A, 600.0 A, 1000 A
|
Resolution
|
0.01 A, 0.1 A, 1 A
|
Accuracy
|
1.6% ± 6 digit (50-60 Hz) {40 A}
|
|
2.5% ± 8 digit (60-500 Hz) {40 A}
|
|
1.5% ± 5 digit (50-60 Hz) {600/1000 A}
|
|
2.5% ± 5 digit (60-500 Hz) {600/1000 A}
|
Crest Factor add 2% into spec for CF > 2
|
3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
|
AC response
|
rms
|
|
Current DC
|
Range
|
40.00 A, 600.0 A, 1000 A
|
Resolution
|
0.01 A, 0.1 A, 1 A
|
Accuracy
|
1.6% ± 6 digit (40 A)
|
|
1.5% ± 5 digit (600/1000 A)
|
|
Voltage AC
|
Range
|
600.0 V
|
Resolution
|
0.1 V
|
Accuracy
|
1.5% ± 5 digit (20-500Hz)
|
AC response
|
rms
|
|
Voltage DC
|
Range
|
600.0 V
|
Resolution
|
0.1 V
|
Accuracy
|
1% ± 4 digit
|
|
Resistance
|
Range
|
400.0 Ω
|
|
4000 Ω
|
Resolution
|
0.1 Ω
|
|
1 Ω
|
Accuracy
|
1% ± 5 digit
|
|
Continuity
|
|
Inrush
|
|
Frequency
|
Range
|
5.0 - 500.0 Hz
|
Accuracy
|
0.5% ± 5 digit
|
Trigger Level
|
10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A
|
|
All precisions refer to 73 °F ± 41 °F (23 °C ± 5 °C)
Less than 64 °F and greater than 82 °F (18 °C and greater than 28 °C)
Environmental Specifications
|
Operating Temperature
|
|
14°F to 122°F (-10 °C to 50 °C)
|
|
Storage Temperature
|
|
-40 °F to 140 °F (-40 °C to 60 °C)
|
|
Operating Humidity
|
|
Non condensing (< 50 °F) (< 10 °C)
|
|
90 % RH (50 °F to 86 °F) (10 °C to 30 °C)
|
|
75 % RH (86 °F to 104 °F) (30 °C to 40 °C)
|
|
45 % RH (104 °F to 122 °F) (40 °C to 50 °C)
|
|
(Without Condensation)
|
|
Operating Altitude
|
|
1 mile (2000 meters) above mean sea level
|
|
Storage Altitude
|
|
7 miles (12,000 meters) above mean sea level
|
|
IP Rating
|
|
Vibration Requirements
|
|
Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis
|
|
Drop Test Requirements
|
|
3 ft (1 m) drop test, six sides, oak floor
|
|
EMI, RFI, EMC
|
|
Instrument unspecified for use in EMC field ≥ 0.1 V/m
|
|
Temperature Coefficients
|
|
0.1x (specified accuracy)/ °C
|
|
(<64 °F or > 82° F)
|
|
(<18 °C or > 28 °C)
|
|
|