Thứ Ba, 12 tháng 1, 2016

FLUKE - Ampe kìm Fluke 307/309 (Fluke 317/319 Clamp Meters) Model: Fluke 307/309

FLUKE - Ampe kìm Fluke 307/309 (Fluke 317/319 Clamp Meters)
Model: Fluke 307/309
Hãng sản xuất: FLUKE – MỸ

                            Kết quả hình ảnh cho Fluke 305 FLUKE
Tính năng Ampe kìm Fluke 307/309:
The two models are economic, compact and offer a range of special features:
  • Unique 40A high-precision low current measurement--0.01A high-resolution, 1.6% high-precision measurement"
  • The clamps are slim, lightweight, and portable, making them ideal for use in small, confined spaces"
  • The large backlight display facilitates readings in dark environments"
  • Starting current (inrush) functionality (319) allows measurement of the starting current of electrical and lighting equipment, for example. (319)
  • Current frequency measurement
  • Precision down to 0.01A and 0.1V
  • 1000A/600A AC/DC current measurement (319/317)
  • 600V AC/DC voltage measurement
  • 4000Ω resistance measurement
  • Continuity beeper
  • Auto off function enhances battery life, meaning the instrument can work when you need it screen store ‘hold’ function for capturing a measurement result on the screen
  • One year warranty

Thông số kỹ thuật Ampe kìm Fluke 307/309:

General Specifications
Digital Display
 6000 count resolution
Low Battery Indication
 Displays a signal when the batteries are below their required voltage
Power Source
 Three AAA IEC LR03 batteries
Jaw opening
 1.45 in (37 mm)
Jaw opening
 1.45 in (37 mm)
Dimensions (L x W x H)
 234 x 74 x 34.8 mm
Weight
 approximately 13.5 oz (384 g) (batteries included)
Automated measurement
 Available in Ohms
Safety
 CE
 EN/IEC 61010-1 and IEC 61010-2-032
 Installation type III, 600V working environment

317 Electrical Specifications
Current AC
Range
 40.00 A, 600.0 A
Resolution
 0.01 A, 0.1 A
Accuracy
 1.6% ± 6 digit (50-60 Hz) {40 A}
 2.5% ± 8 digit (60-500 Hz) {40 A}
 1.5% ± 5 digit (50-60 Hz) {600 A}
 2.5% ± 5 digit (60-500 Hz) {600 A}
Crest Factor add 2% into spec for CF > 2
 3.0 Max @ 500 A, 2.5 Max @ 600 A
AC response
 rms
Current DC
Range
 40.00 A, 600.0 A
Resolution
 0.01 A, 0.1 A
Accuracy
 1.6% ± 6 digit (40 A)
 1.5% ± 5 digit (600 A)
Voltage AC
Range
 600.0 V
Resolution
 0.1 V
Accuracy
 1.5% ± 5 digit (20-500Hz)
AC response
 rms
Voltage DC
Range
 600.0 V
Resolution
 0.1 V
Accuracy
 1% ± 4 digit
Resistance
Range
 400.0 Ω, 4000 Ω
Resolution
 0.1 Ω, 1 Ω
Accuracy
 1% ± 5 digit
Continuity
 ≤ 30 Ω
Inrush
Integration time
 N/A
Frequency
Range
 N/A
Accuracy
 N/A
Trigger Level
 N/A

319 Electrical Specifications
Current AC
Range
 40.00 A, 600.0 A, 1000 A
Resolution
 0.01 A, 0.1 A, 1 A
Accuracy
 1.6% ± 6 digit (50-60 Hz) {40 A}
 2.5% ± 8 digit (60-500 Hz) {40 A}
 1.5% ± 5 digit (50-60 Hz) {600/1000 A}
 2.5% ± 5 digit (60-500 Hz) {600/1000 A}
Crest Factor add 2% into spec for CF > 2
 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
AC response
 rms
Current DC
Range
 40.00 A, 600.0 A, 1000 A
Resolution
 0.01 A, 0.1 A, 1 A
Accuracy
 1.6% ± 6 digit (40 A)
 1.5% ± 5 digit (600/1000 A)
Voltage AC
Range
 600.0 V
Resolution
 0.1 V
Accuracy
 1.5% ± 5 digit (20-500Hz)
AC response
 rms
Voltage DC
Range
 600.0 V
Resolution
 0.1 V
Accuracy
 1% ± 4 digit
Resistance
Range
 400.0 Ω
 4000 Ω
Resolution
 0.1 Ω
 1 Ω
Accuracy
 1% ± 5 digit
Continuity
 ≤ 30 Ω
Inrush
Integration time
 100 ms
Frequency
Range
 5.0 - 500.0 Hz
Accuracy
 0.5% ± 5 digit
Trigger Level
 10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A
All precisions refer to 73 °F ± 41 °F (23 °C ± 5 °C)

Less than 64 °F and greater than 82 °F (18 °C and greater than 28 °C)


Environmental Specifications
Operating Temperature
 14°F to 122°F (-10 °C to 50 °C)
Storage Temperature
 -40 °F to 140 °F (-40 °C to 60 °C)
Operating Humidity
 Non condensing (< 50 °F) (< 10 °C)
 90 % RH (50 °F to 86 °F) (10 °C to 30 °C)
 75 % RH (86 °F to 104 °F) (30 °C to 40 °C)
 45 % RH (104 °F to 122 °F) (40 °C to 50 °C)
 (Without Condensation)
Operating Altitude
 1 mile (2000 meters) above mean sea level
Storage Altitude
 7 miles (12,000 meters) above mean sea level
IP Rating
 IP40
Vibration Requirements
 Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis
Drop Test Requirements
 3 ft (1 m) drop test, six sides, oak floor
EMI, RFI, EMC
 Instrument unspecified for use in EMC field ≥ 0.1 V/m
Temperature Coefficients
 0.1x (specified accuracy)/ °C
 (<64 °F or > 82° F)
 (<18 °C or > 28 °C)

Không có nhận xét nào:

Đăng nhận xét