FLUKE
- Ampe kìm Fluke 324 (Fluke 324 True-rms Clamp Meter)
Model:
Fluke 324
Hãng
sản xuất: FLUKE – MỸ
Tham
khảo: http://www.fluke.com/fluke/vnen/clamp-meters/Fluke-324-True-rms-Clamp-Meter.htm?PID=74605
Tính năng Ampe kìm Fluke 324:
Measurement
capability:
-
400
A ac current measurement
-
600
V ac and dc voltage measurement
-
True-rms
ac voltage and current for accurate measurements on non-linear signals
-
Resistance
measurement up to 40 kΩ with continuity detection
-
Temperature
and capacitance measurement
Features:
-
Slim,
ergonomic design
-
Large,
easy to read backlight display
-
CAT
IV 300V/CAT III 600 V safety rating
-
Hold
button
-
Two-year
warranty
Soft carrying case
Thông số kỹ thuật Ampe
kìm Fluke 324:
-
Fluke 324 True-rms Clamp Meter measurements and
optimized ergonomics make it the best general troubleshooting tool for commercial
and residential electricians. The Fluke 324 is designed to verify the presence
of load current, AC voltage and continuity of circuits, switches, fuses and
contacts. The Fluke 324 clamp meter is ideally suited for current measurements
up to 400A in tight cable compartments. 324 model also includes temperature and
capacitance measurement capabilities. The design of the Fluke 324 improve on
the designs of the old clamp meters to make them tougher and easier to use. The
Fluke 324 is rugged, reliable and precise. Fluke 324 True-rms Clamp Meter comes
complete with: test leads, soft case, user's manual
|
|
Model: FLUKE 323
|
Model: FLUKE 324
|
Model: FLUKE 325
|
AC current
|
Range
|
400.0 A
|
40.00 A/400.0 A
|
40.00 A/400.0 A
|
Accuracy
|
2 % ± 5 digits (45 Hz to 65 Hz) 2.5 % ± 5 digits (65 Hz to 400 Hz)
|
1.5 % ± 5 digits (45 Hz to 400 Hz) Note: Add 2 % for position sensitivity
|
2 % ± 5 digits (45 Hz to 65 Hz) 2.5 % ± 5 digits (65 Hz to 400 Hz)
|
|
DC current
|
Range
|
|
|
40.00 A/400.0 A
|
Accuracy
|
|
|
2 % ± 5 digits
|
|
AC voltage
|
Range
|
600.0 V
|
600.0 V
|
600.0 V
|
Accuracy
|
1.5 % ± 5 digits
|
1.5 % ± 5 digits
|
1.5 % ± 5 digits
|
|
DC voltage
|
Range
|
600.0 V
|
600.0 V
|
600.0 V
|
Accuracy
|
1.0 % ± 5 digits
|
1.0 % ± 5 digits
|
1.0 % ± 5 digits
|
|
Resistance
|
Range
|
400.0 Ω/ 4000 Ω
|
400.0 Ω/ 4000 Ω
|
400.0 Ω/ 4000 Ω/ 40.00 kΩ
|
Accuracy
|
1.0 % ± 5 digits
|
1.0 % ± 5 digits
|
1.0 % ± 5 digits
|
|
Continuity
|
≤ 70 Ω
|
≤ 30 Ω
|
≤ 30 Ω
|
|
Capacitance
|
|
100.0 μF to 1000 μF
|
100.0 μF to 1000 μF
|
|
Frequency
|
|
|
5.0 Hz to 500.0 Hz
|
|
AC response
|
True-rms
|
True-rms
|
True-rms
|
|
Backlight
|
|
Yes
|
Yes
|
|
Data hold
|
Yes
|
Yes
|
Yes
|
|
Contact temperature
|
|
-10.0 °C to 400.0 °C (14.0 °F to 752.0 °F)
|
-10.0 °C to 400.0 °C (14.0 °F to 752.0 °F)
|
|
Min/Max
|
|
|
Yes
|
|
Category rating
|
CAT III 600 V CAT IV 300 V
|
CAT III 600 V CAT IV 300 V
|
CAT III 600 V CAT IV 300 V
|