Tính năng Ampe kìm đo rò rỉ điện AC Fluke 360:
  • Measurement of leakage current with 3 mA range and 1 µA of resolution, for accurate monitoring of insulation erosion
  • Broad range of measurement, from 1 µA up to 60 A, for all installation needs
  • Advanced shielding to ensure accurate results when measuring near other conductors
  • The high durability clamp construction can withstand over 50,000 operations, added ruggedness that extends the life of your leakage clamp.
  • Easy-to-carry, pocket-sized leakage current tester with wide 40 mm (1.5 in) jaw size
  • Handy “Display-Hold” button for capturing leakage current readings in hard-to-reach places
  • Auto power-off, with warning buzzer, saves battery life
  • Conformance to IEC1010 and EMC standard for confident measurements
  • Meets all of the applications and performance classes in safety standard VDE0404-4 and VDE0702 for leakage current and differential current measurement of electrical appliances

Thông số kỹ thuật Ampe kìm đo rò rỉ điện AC Fluke 360:

General Specifications
Method of detection
 Mean value
Display
Digital display:
 3200 counts
Bar-graph display:
 32 segments, LCD
Measurement Cycle
 2 times/second (Digital display), 12 times/second (Bar-graph display)
Range switching
 Auto-range
Ambient temperature and humidity
 0 °C to 50 °C, 80 % RH or less (no condensation)
Temperature coefficient
 0.05% of range/°C or less (within the ranges of 0 °C to 18 °C and 28 °C to 50 °C for measurement of 0-50 A)
Influence of external magnetic field
 0.0005% typical
Influence of conductor position
 Within accuracy
Circuit voltage
 <300 Vrms
Safety standard
 EN 61010-1, EN 61010-2-032, 300 V CAT III, Pollution Degree 2
Withstanding voltage
 3.7 kV ac
Battery type
 1 x 3 V Lithium battery (button cell) CR2032
Battery life
 Approx. 90 hours (when continuously used)
Auto power-off
 Approx. 10 minutes
Diameter of measurable conductor
 40 mm max.
Weight
 200 g
Dimension
 176 mm x 70 mm x 25 mm
Operating altitude
 2000 m


Electrical Specification
Specifications at
 23 ± 5 ºC, 80 % RH max
Accuracy
 (% readout + value of least significant digit)
3 mA
 Resolution: 0.001 mA
Accuracy:
 1% + 5
Max Permissible current:
 60 A rms
30 mA
 Resolution: 0.01 mA
Accuracy:
 1% + 5
Max Permissible current:
 60 A rms
30 A
 Resolution: 0.01 A
Accuracy:
 1% + 5
Max Permissible current:
 60 A rms
60 A
 Resolution: 0.1 A
Accuracy:
 5% + 5 
Max Permissible current:
 60 A rms
Mean value detection and rms-value calibration
Accuracy specified at:
 50/60 Hz