FLUKE - Ampe kìm Fluke 355 và Fluke 353 True-rms
2000 A
Model:
Fluke 355 và Fluke 353 True-rms 2000 A
Hãng
sản xuất: FLUKE – MỸ
Tính năng Ampe kìm Fluke 355 và Fluke 353 True-rms 2000
A:
- Reliably handle a wide range of high-current
applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc
- The large 58 mm (2.3 in) jaw capacity is suitable
for large or multiple conductors
- CAT IV 600 V, CAT III 1000 V rating for added
user protection
- In-rush current measurement captures ‘power-on’
surge current with accuracy and repeatability
- High voltage measurement of 1000 V ac + dc
true-rms, 600 V ac, and 1000 V dc allows the user to perform multiple
tests with only one tool (355 only)
- Resistance to 400K ohms coupled with a continuity
beeper provide the convenience of a multimeter in a clamp meter. (355
only)
- Accurately measure frequency up to 1 kHz for
optimum troubleshooting
- Quickly analyze readings using the MIN, MAX, and
AVG functions
- A large backlit display allows for easy
visibility in low-lit areas
- Use the display hold feature to capture readings
even when the display cannot be viewed
- Use the low-pass filter to smooth out noisy loads
and stabilize readings
Thông số kỹ thuật Ampe kìm Fluke 355 và Fluke 353
True-rms 2000 A:
Electrical specifications
|
Current measurement dc and ac 10 Hz to 100 Hz
|
Range : 40 A
|
Resolution: 10 mA
Accuracy, A: 1.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF: 2.50 A
Trigger Level for Hz Filter ON: 0.50 A
|
Range : 400 A
|
Resolution: 100 mA
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF: 2.5 A
Trigger Level for Hz Filter ON: 2.5 A
|
Range : 2000 A; 1400 ac rms
|
Resolution: 1 A
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF: 8 A
Trigger Level for Hz Filter ON: 8 A
|
|
Crest Factor (50/60 Hz)
|
Range : 40 A
|
Crest Factor* : 2 @ 33 A, 2.4 @ 27 A
|
Range : 400 A
|
Crest Factor* : 2 @ 330 A, 2.4 @ 270 A
|
Range : 2000 A; 1400 ac rms
|
Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A
|
|
Current measurement ac 100.1 Hz to 1 kHz
|
Range : 40 A
|
Resolution: 10 mA
Accuracy > 10 A : 3.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF : 2.50 A
Trigger Level for Hz Filter ON : 0.50 A
|
Range : 400 A
|
Resolution: 100 mA
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF : 2.5 A
Trigger Level for Hz Filter ON : 2.5 A
|
Range : 2000 A; 1400 ac rms
|
Resolution: 1 A
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF : 8 A
Trigger Level for Hz Filter ON : 8 A
|
|
Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V
respectively.)
|
Range : 4 V
|
Resolution: 1 mV
Accuracy: 1 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
|
Range : 40 V
|
Resolution: 10 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
|
Range : 400 V
|
Resolution: 100 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
|
Range : 600 V ac rms
|
Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
|
Range : 1000 V dc
|
Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
|
|
Voltage measurement (355 only) ac 100.1 Hz to 1 kHz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V
respectively.)
|
Range: 4 V
|
Resolution: 1 mV
Accuracy: 3 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
|
Range: 40 V
|
Resolution: 10 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
|
Range: 400 V
|
Resolution: 100 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
|
Range: 600 V ac rms
|
Resolution: 1 V
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
|
|
Ohms measurement (355 only)
|
Range: 400 Ω
|
Resolution: 0.1 Ω
Accuracy: 1.5 % + 5 digits
|
Range: 4 kΩ
|
Resolution: 1 Ω
Accuracy: 1.5 % + 5 digits
|
Range: 40 kΩ
|
Resolution: 10 Ω
Accuracy: 1.5 % + 5 digits
|
Range: 400 kΩ
|
Resolution: 100 Ω
Accuracy: 1.5 % + 5 digits
|
|
Continuity beeper (355 only)
|
|
On at ≤ 30 Ω
|
|
Off at ≥ 100 Ω
|
|
Frequency measurement
|
Measurement range
|
5.0 Hz to 1 kHz
|
Resolution
|
0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
|
Accuracy – 5.0 Hz to 100 Hz
|
0.2 % + 2 counts
|
Accuracy – 100.1 Hz to 1 kHz
|
0.5 % + 5 counts
|
Trigger level
|
Refer to current and voltage tables
|
|
*Add 2 % to error spec for CF > 2
General specifications
|
Batteries
|
|
Six 1.5 V AA NEDA 15 A or IEC LR6
|
|
Battery life (with typical usage, backlight off)
|
|
Test leads
|
|
Weight
|
|
Jaw size
|
|
Dimensions (LxWxD)
|
|
300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
|
|
Safety rating
|
|
IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III
|
|
Environmental specifications
|
Operating temperature
|
|
32 °F to + 122 °F (0 °C to +50 °C)
|
|
Storage temperature
|
|
-4 °F to 140 °F (-20 °C to +60 °C)
|
|
Operating humidity
|
|
0 to 95 % (non-condensing)
|
|
Operating altitude
|
|
Storage altitude
|
|
IP rating
|
|
Drop test requirements
|
|
EMI, RFI, EMC
|
|
FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m,
performance criteria B, EN61325
|
|
Temperature coefficients
|
Current:
|
0.1 % of reading per °C outside 22 °C to 24 °C
|
Voltage:
|
0.1 % of reading per °C outside 22 °C to 24 °C
|
|
Không có nhận xét nào:
Đăng nhận xét