Display
|
|
Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2
level backlight
|
|
|
Power supply
|
|
|
Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6
|
|
Battery life typically
|
|
> 10 hours (backlight on full)
|
|
> 12 hours (backlight reduced)
|
|
Battery Eliminator BE345
|
Input
|
110/230 V 50/60 Hz
|
Output
|
15 V dc, 300 mA
|
|
Ambient conditions (For indoor use only)
|
Reference conditions
|
|
All accuracies stated at 23˚C ± 1˚C (73.4 °F ± 1.8 °F)
|
|
Operating temperature
|
|
0 °C to 50 °C (32 °F to 122 °F)
|
|
Temperature coefficient of current
|
|
Temperature coefficient of voltage
|
|
Maximum relative humidity
|
|
80 % for temperatures up to 31 °C (87 °F) decreasing
linearly to 50 % relative humidity at 40 °C (104 °F)
|
|
Maximum operating altitude
|
|
Electrical safety
|
Maximum safe working voltages
|
|
Safety IEC 61010-1 600 V CAT IV double or reinforced
insulation, pollution degree 2
|
|
|
|
Current measurement
|
|
600 V ac rms or dc between uninsulated conductor and ground
|
|
Voltage measurement
|
|
600 V ac rms or dc between either input terminal and
ground, or 825 V between energized phase voltages (delta power
config.)
|
|
EMC
|
Emission
|
|
IEC/EN 61326-1:1997 class A
|
|
Immunity
|
|
IEC/EN 61326-1:1997 Annex C Performance Criterion B
|
|
Mechanical
|
Dimensions (length x width x depth)
|
|
300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
|
|
Weight including batteries
|
|
Jaw opening
|
|
Jaw capacity
|
|
Cleaning
|
|
The unit can be cleaned with an Isopropanol impregnated
cloth. Do not use abrasives or other solvents.
|
|
Electrical data
|
All accuracies stated at 23 °C ± 1 °C (73.4 °F ± 1.8 °F). See Ambient
conditions specifications for temperature coefficients.
|
|
Current measurement (dc, dc rms, ac rms)
|
Measuring range
|
|
0 to 2000 A dc or 1400 ac rms
|
|
Autorange facility
|
|
Resolution
|
|
10 mA in 40 A range
|
|
100 mA in 400 A range
|
|
1 A in 2000 A range
|
|
Accuracy: DC and dc rms
|
I > 10 A:
|
± 1.5 % rdg ± 5 digits
|
I < 10 A:
|
± 0.2 A
|
|
Accuracy: AVG
|
I > 10 A:
|
± 3 % rdg ± 5 digits
|
I < 10 A:
|
± 0.5 A
|
|
Accuracy: Pk
|
I > 10 A:
|
± 5 % rdg ± 5 digits
|
I < 10 A:
|
± 0.5 A
|
|
Accuracy: AHr
|
I > 10 A:
|
± 2 % rdg ± 5 digits
|
I < 10 A:
|
± 0.5 AHr
|
|
Accuracy: CF (Crest Factor)
|
1.1 ≤ CF < 3:
|
± 3 % rdg ± 5 digits
|
3 ≤ CF < 5:
|
± 5 % rdg ± 5 digits
|
Resolution:
|
0.01
|
|
Accuracy: RPL (Ripple)
|
2 % ≤ RPL < 100 %:
|
± 3 % rdg ± 5 digits
|
100 % ≤ RPL < 600 %:
|
± 5 % rdg ± 5 digits
|
Resolution:
|
0.1 %
|
Idc > 5 A, Iac > 2 A
|
|
|
All measurements dc and 15 Hz to 1 kHz
Maximum overload 10,000 A or rms x frequency < 400,000
Amps rms is a true-rms measurement (ac + dc)
|
|
Voltage measurement (dc, dc rms, ac rms)
|
Measuring range
|
|
Autorange facility
|
|
4 V / 40 V / 400 V / 750 V
|
|
Resolution
|
|
1 mV in 4 V range
|
|
10 mV in 40 V range
|
|
100 mV in 400 V range
|
|
1 V in 750 V range
|
|
Accuracy: DC and dc rms
|
V > 1 V:
|
± 1 % rdg ± 5 digits
|
V < 1 V:
|
± 0.02 V
|
|
Accuracy: AVG
|
V > 1 V:
|
± 3 % rdg ± 5 digits
|
V < 1 V:
|
± 0.03 V
|
|
Accuracy: Pk
|
V > 1 V:
|
± 5 % rdg ± 5 digits
|
V < 1 V:
|
± 0.03 V
|
|
Accuracy: CF (Crest Factor)
|
1.1 ≤ CF < 3:
|
± 3 % rdg ± 5 digits
|
3 ≤ CF < 5:
|
± 5 % rdg ± 5 digits
|
Resolution:
|
0.01
|
|
Accuracy: RPL (Ripple)
|
2 % ≤ RPL < 100 %:
|
± 3 % rdg ± 5 digits
|
100 % ≤ RPL < 600 %:
|
± 5 % rdg ± 5 digits
|
Resolution:
|
0.1 %
|
Vdc > 0.5 V, Vac > 0.2 V
|
|
|
|
|
All measurements dc and 15 Hz to 1 kHz
Maximum overload 1,000 V rms
Volts rms is a true-rms measurement (ac + dc)
|
|
Harmonics
|
THD (Total Harmonic Distortion)
|
1 % ≤ THD < 100 %:
|
± 3 % rdg ± 5 digits
|
100 % ≤ THD < 600 %:
|
± 5 % rdg ± 5 digits
|
Resolution:
|
0.1 %
|
|
DF (Distortion Factor)
|
1 % ≤ DF < 100 %:
|
± 3 % rdg ± 5 digits
|
Resolution:
|
0.1 %
|
H02 ≤ Vharm < H13:
|
± 5 % ± 2 digits
|
H13 ≤ Vharm ≤ H30:
|
± 10 % ± 2 digits
|
|
|
|
All measurements up to 30th harmonic (40th harmonic for 15
Hz to 22 Hz)
Frequency range of fundamental F0 15 Hz to 22 Hz and 45 Hz to 65 Hz
Vacrms > 1V
|
|
Watts measurement (single- and three-phase) (dc, dc rms, ac rms)
|
Measuring range
|
|
0 to 1650 kW dc or 1200 kW ac
|
|
Autoranging facility
|
|
4 kW, 40 kW, 400 kW, 1650 kW
|
|
Resolution
|
|
1 W in 4 kW
|
|
10 W in 40 kW
|
|
100 W in 400 kW
|
|
1 kW in 1200 kW
|
|
Accuracy
|
|
2.5 % rdg ± 5 digits
|
|
W1Ø < 2 kW ± 0.08 kW
|
|
W3Ø < 4 kW ± 0.25 kW
|
|
VA measurement (single- and three-phase) (dc, dc rms, ac rms)
|
Measuring range
|
|
0 to 1650 kVA dc or 1200 kVA ac
|
|
Autorange facility
|
|
4 kVA, 40 kVA, 400 kVA, 1650 kVA
|
|
Resolution
|
|
1 VA in 4 kVA
|
|
10 VA in 40 kVA
|
|
100 VA in 400 kVA
|
|
1 kVA in 1200 kVA
|
|
Accuracy
|
VA > 2 kVA:
|
2.5 % rdg ± 5 digits
|
VA < 2 kVA:
|
± 0.08 kVA
|
|
VAR measurement (single- and three-phase)
|
Measuring range
|
|
Autorange facility
|
|
4 kVAR, 40 kVAR, 400 kVAR, 1200 kVAR
|
|
Resolution
|
|
1 VAR in 4 kVAR
|
|
10 VAR in 40 kVAR
|
|
100 VAR in 400 kVAR
|
|
1 kVAR in 1200 kVAR
|
|
Accuracy
|
VAR > 4 kVAR:
|
± 2.5 % rdg ± 5 digits
|
VAR < 4 kVAR:
|
± 0.25 kVAR
|
|
Power factor range
|
|
Power factor (single- and three-phase)
|
Measuring range
|
|
0.3 capacitive to 1.0 and 1.0 to 0.3 inductive (72.5°
capacitive to 0° and 0° to 72.5° inductive)
|
|
Resolution
|
|
Accuracy
|
|
Frequency range
|
|
Displacement power factor (single- and three-phase)
|
Measuring range
|
|
0.3 capacitive to 1.0 and 1.0 to 0.3 inductive (72.5°
capacitive to 0° and 0° to 72.5° inductive)
|
|
Resolution
|
|
Accuracy
|
|
Frequency range
|
|
15 Hz to 22 Hz and 45 Hz to 65 Hz
|
|
Kilowatt hour (kWHr)
|
Measuring range
|
|
Autorange facility
|
|
4 kWHr, 40 kWHr, 400 kWHr, 4,000 kWHr, 40,000 kWHr
|
|
Resolution
|
|
1 WHr in 4 kWHr Range
|
|
10 WHr in 40 kWHr Range
|
|
100 WHr in 400 kWHr Range
|
|
1 kWHr in 4,000 kWHr Range
|
|
10 kWHr in 40,000 kWHr Range
|
|
Accuracy
|
kWHr > 2 kWHr:
|
± 3 % ± 5 digits
|
kWHr < 2 kWHr:
|
± 0.08 kWHr
|
|
All Watts /VA /VAR /PF measurements
|
Frequency range:
|
DC and 15 Hz to 1 kHz
|
Current range:
|
10 A to 1400 A rms
|
Voltage range:
|
1 V to 825 V rms
|
Maximum input:
|
825 V rms/1400 A rms
|
Maximum overload:
|
1000 V rms/10,000 A All measurements dc and 15 Hz to 1 kHz.
Maximum overload 10,000 A or rms x frequency < 400,000
|
|
Frequency measurement (from current or voltage sources)
|
Measuring range
|
|
Resolution
|
|
Accuracy
|
|
15 to 22 Hz ± 0.5 % rdg
|
|
40 Hz to 70 Hz ± 0.5 % rdg
|
|
15 Hz to 1000 Hz ± 1% rdg
|
|
Current range
|
|
Voltage range
|
|
Scope function
|
Current measurement
|
Ranges:
|
10 A / 20 A / 40 A / 100 A / 200 A / 400 A / 1000 A / 2000
A
|
Resolution:
|
1 A in 40 A
10 A in 400 A
50 A in 2000 A
|
Accuracy:
|
± 3 % rdg ± 1 pixel
|
Maximum overload:
|
10,000 A
|
|
Voltage measurement
|
Ranges:
|
4 V / 10 V / 20 V / 40 V / 100 V / 200 V / 400 V / 1000 V
|
Resolution:
|
100 mV in 4 V
1 V in 40 V
10 V in 400 V
31.25 V in 1000 V
|
Accuracy:
|
± 2 % rdg ± 1 pixel
|
Maximum overload:
|
1000 V rms
|
Frequency range:
|
DC and 15 Hz to 600 Hz
|
|
Time base
|
|
2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div
|
|
Refresh rate
|
|
Maximum sampling rate
|
|
Inrush current function
|
Ranges
|
|
Resolution
|
|
10 mA in 40 A range
|
|
100 mA in 400 A range
|
|
1 A in 2000 A range
|
|
Accuracy
|
I > 10 A:
|
± 5 % rdg ± 1 pixel
|
I < 10 A:
|
± 0.5 A
|
|
All measurements dc and 15 Hz to 1 kHz
|
|
Maximum overload
|
|
Maximum overload 10,000 A or rms x frequency < 400,000
|
|
Amps rms is a true-rms measurement (ac + dc)
|
|
Capture time
|
|
1 s, 3 s, 10 s, 30 s, 100 s, and 300 s
|
|
Maximum sampling rate
|
|
Interface
|
|
|
|
|
Power Log software for download, analysis and reporting
|
|
|
|
345 Upgrade Utility for installing a new firmware version
|
|
Logging Memory
|
Logging areas
|
|
Three areas that can be used individually or combined into
one large area
|
|
Averaging periods
|
|
1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 15 min,
and custom
|
|
Logging Times
|
Volts and current mode
|
Average time
|
Logging time
(1 area)
|
1 s
|
1 h 49 m
|
2 s
|
3 h 38 m
|
5 s
|
9 h 6 m
|
10 s
|
18 h 12 m
|
30 s
|
2 d 6 h 36 m
|
1 min
|
4 d 13 h 12 m
|
5 min
|
22 d 18 h 0 m
|
10 min
|
45 d 12 h 0 m
|
15 min
|
68 d 6 h 0 m
|
|
Logging time
(3 areas)
|
1 s
|
5 h 12 m
|
2 s
|
10 h 24 m
|
5 s
|
1 d 2 h 00 m
|
10 s
|
2 d 4 h 00 m
|
30 s
|
6 d 12 h 1 m
|
1 min
|
13 d 0 h 12 m
|
5 min
|
65 d 0 h 15 m
|
10 min
|
130 d 0 h 30 m
|
15 min
|
195 d 0 h 45 m
|
|
V & A harmonics mode
|
Average time
|
Logging time
(1 area)
|
1 s
|
0 h 34 m
|
2 s
|
1 h 8 m
|
5 s
|
2 h 52 m
|
10 s
|
5 h 44 m
|
30 s
|
17 h 13 m
|
1 m
|
1 d 10 h 26 m
|
5 m
|
7 d 4 h 10 m
|
10 m
|
14 d 8 h 20 m
|
15 m
|
21 d 12 h 30 m
|
|
Logging time
(3 areas)
|
1 s
|
1 h 38 m
|
2 s
|
3 h 16 m
|
5 s
|
8 h 11 m
|
10 s
|
16 h 23 m
|
30 s
|
2 d 1 h 11 m
|
1 m
|
4 d 2 h 23 m
|
5 m
|
20 d 11 h 25 m
|
10 m
|
81 d 0 h 50 m
|
15 m
|
121 d 13 h 15 m
|
|
single- and three-phase power mode
|
Average time
|
Logging time
(1 area)
|
1 s
|
1 h 40 m
|
2 s
|
3 h 21 m
|
5 s
|
8 h 22 m
|
10 s
|
16 h 45 m
|
30 s
|
2 d 2 h 17 m
|
1 m
|
4 d 4 h 35 m
|
5 m
|
20 d 22 h 55 m
|
10 m
|
41 d 21 h 50 m
|
15 m
|
62 d 20 h 45 m
|
|
Logging time
(3 areas)
|
1 s
|
4 h 47 m
|
2 s
|
9 h 34 m
|
5 s
|
23 h 57 m
|
10 s
|
1 d 23 h 54 m
|
30 s
|
5 d 23 h 25 m
|
1 m
|
11 d 23 h 25 m
|
5 m
|
59 d 21 h 5 m
|
10 m
|
119 d 18 h 10 m
|
15 m
|
179 d 15 h 15 m
|
|
|
|
|
|