Tính năng Ampe kìm quá trình đo mA Fluke 773:

  • Best in class 0.2 % accuracy
  • 0.01 mA resolution and sensitivity
  • Measure 4 to 20 mA signals without ”breaking the loop”
  • Measure mA signals for PLC and control system analog I/O
  • Dual backlit display with both mA measurement and percent of 4 to 20 mA span
  • Measurement Spotlight illuminates hard to see wires in dark enclosures
  • Detachable clamp with extension cable for measurements in tight locations
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
  • Automatically change the 4 to 20 mA output for remote testing
  • Power saving features, auto-off, backlight timeout extend battery life
  • Hold function captures and displays changing measurements
  • Measure 4 to 20 mA signals with in-circuit measurement
  • Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
  • Source 4 to 20 mA signals for testing control system I/O or I/Ps
  • mA output linear ramp or 25% step output
  • Automatically change the 4 to 20 mA output for remote testing
  • DC voltage measurement to verify 24V power supplies or voltage I/O signals
  • Source DC voltage to test input devices that accept a 1-5V or 0 to 10V signals
  • Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp
  • Enables milliamp signal logging to a separate logging device without breaking the loop
  • Output mA signal enables a logging DMM or other device to record the 4- to 20 mA signal without breaking the loop
  • mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal
  • Apply a mA input signal to a device and measure its’ 4-20 mA output on devices such as valves or mA isolators
  • Voltage output linear ramp or 25% step output
  • Automatically change the voltage output for remote testing

Thông số kỹ thuật Ampe kìm quá trình đo mA Fluke 773:

Diameter of measurable conductor
0.177” or 4.5 mm max
Operating temperature
-10 to 50 ºC
Storage Temperature
-25 to 60ºC
Operating Humidity
< 90% @ <30 ºC, < 75% @ 30 to 55ºC
Operating Altitude
0 to 2000 m
IP Rating
IP 40
Size
44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in)
Weight
410 g, (14.4 oz)
Vibration
Random 2 g, 5 to 500 Hz
Shock
1 meter drop test (except the jaw)
EMI/RFI
Meets EN61326-1
Note: For current measurement w/ JAW, add 1mA to
specification for EMC field strengths of 1V/m up to 3V/m.
Temperature Coefficient
0.01% ºC
(<18ºC or > 28ºC)
Power, battery life
(4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms
Warranty
Three years for electronics
one year for cable and clamp assembly


Functional Specifications
mA measurement
(Measured by clamp) 771/772/773 
Resolution and Range:          0 to 20.99 mA
Accuracy:                             0.2%+2 counts
Resolution and Range:          21.0 mA to 100.0 mA
Accuracy:                             1% + 5 counts
mA measurement
(Measured in series with test jacks) 772/773 
Resolution and Range:          0 to 24.00 mA
Accuracy:                             0.2% + 2counts 
mA source (Maximum mA Drive:
24 mA into 1,000 ohms) 
Resolution and Range:          0 to 24.00 mA
Accuracy:                             0.2% + 2counts 
mA simulate
(Maximum voltage 50 V dc) 
Resolution and Range:          0 to 24.00 mA
Accuracy:                             0.2% + 2counts
Voltage source (2 mA maximum drive current)
Resolution and Range:          0 to 10.00 V dc
Accuracy:                             0.2% + 2counts
Voltatge Mesaure
Resolution and Range:          0 to 30.00 V dc
Accuracy:                             0.2% + 2counts