Trang

Thứ Tư, 13 tháng 1, 2016

FLUKE – Đồng hồ điện vạn năng kỹ thuật số Fluke 17B+ Model: Fluke 17B+

FLUKE – Đồng hồ điện vạn năng kỹ thuật số Fluke 17B+

Model: Fluke 17B+
Hãng sản xuất: FLUKE – MỸ
Kết quả hình ảnh cho Fluke 15B+ FLUKE
Tính năng Đồng hồ điện vạn năng kỹ thuật số Fluke 17B+:
  • 600 V Cat III safety rating
  • 50% bigger display with bright white backlight
  • Over-voltage indicator
  • Frequency and temperature measurement
  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A current
  • Diode test, data hold

Thông số kỹ thuật Đồng hồ điện vạn năng kỹ thuật số Fluke 15B+:
Accuracy Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).
Function
Range
Resolution
Accuracy
AC volts 
(40 Hz to 500Hz)1
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0 % + 3
DC volts
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5 % + 3
AC millivolts
400.0 mV
0.1 mV
3.0 % + 3
DC millivolts
400.0 mV
0.1 mV
1.0 % + 10
Diode test2
2.000 V
0.001 V
10%
Resistance 
(Ohms)
400.0 Ω
4.000 k
Ω
40.00 k
Ω
400.0 k
Ω
4.000 M
Ω
40.00 M
Ω
0.1 Ω
0.001 k
Ω
0.01 k
Ω
0.1 k
Ω
0.001 M
Ω
0.01 M
Ω
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
Capacitance3
40.00 nF
400.0 nF
4.000
μF
40.00
μF
400.0
μF
1000
μF
0.01 nF
0.1 nF
0.001
μF
0.01
μF
0.1
μF
1
μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency1
Hz
(10 Hz – 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
0.1 % + 3
Duty Cycle1
1 % to 99 %
0.1 %
1 % typical 4
AC current μA
(40 Hz to 400 Hz)
400.0 μA
4000
μA
0.1 μA
1
μA
1.5 % + 3
AC current mA
(40 Hz to 400 Hz)
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3
AC current A
(40 Hz to 400 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
DC current μA
400.0 μA
4000
μA
0.1 μA
1
μA
1.5 % + 3
DC current mA
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3
DC current A
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
Temperature
50 °C- 400 °C
0 °C- 50 °C
-55 °C- 0 °C
0.1C
2 % ± 1 °C
± 2 °C
9 % ± 2 °C
Backlight
-
-
Yes
1All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
4Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %.

Function
Overload Protection
Input Impedance (Nominal)
Common Mode Rejection Ratio
Normal Mode Rejection Ratio
AC volts
1000 V 1
>10 MΩ <100 pF
>60 dB at dc,
50 Hz or 60 Hz
-
AC millivolts
400 mV
>1MΩ, <100 pF
>80 dB at 50 Hz or 60 Hz
-
DC volts
1000 V 1
>10 MΩ <100 pF
>100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts
400 mV
>1MΩ, <100 pF
>80 dB at 50 Hz or 60 Hz
-
1 106 V Hz Max

General Specifications
Maximum voltage between any terminal and earth ground
1000 V
Display (LCD)
4000 counts, updates 3/sec
Battery type
2 AA, NEDA 15A, IEC LR6
Battery life
500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
Temperature
Operating
0 °C to 40 °C
Storage
-30 °C to 60 °C
Relative Humidity
Operating humidity
Non-condensing (<10°C)
≤90% RH at 10 °C to 30 °C;
 
≤75% RH at 30 °C to 40 °C
40 MΩ range
≤80% RH at 10 °C to 30 °C;
 
≤70% RH at 30 °C to 40 °C
Altitude
Operating
2000 m
Storage
12,000 m
Temperature coefficient
0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs
440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only.
Size (HxWxL)
183 x 91 x 49.5 mm
Weight
455 g
IP rating
IP 40
Safety
IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
Electromagnetic environment
IEC 61326-1: Portable
Electromagnetic compatibility
Applies to use in Korea only
Class A equipment (industrial broadcasting & communication equipment)1
1
 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or
user should take notice of it. This equipment is intended for use in business environments and is not to be
used in homes.