The CNX 3000 Wireless Multimeter has all the essentials for convenient test and measurement troubleshooting.
  • AC and DC voltage measurements to 1000V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX Recording
  • CAT III 1000 V, Cat IV 600 V; IP54
Plus, the CNX wireless enabled modules measure AC voltage, AC current and temperature, which display on the CNX Wireless Multimeter. Choose a standard clamp or flexible clamp to measure AC current. Mix and match modules to suit your unique measurement needs. Read the primary measurement on the main display, and up to three modules at any one time. Modules are available separately or as part of CNX kits.

Thông số kỹ thuật Đồng hồ điện vạn năng kỹ thuật số không dây Fluke CNX 3000:
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).

Detailed Specifications
AC Voltage
Range ¹
Resolution
Accuracy ² ³
45 Hz to 500 Hz
500 Hz to 1 kHz
600.0 mV
0.1 mV
1.0 % + 3
2.0 % + 3
6.000 V
0.001 V
60.00 V
0.01 V
600.0 V
0.1 V
1000 V
1 V
¹ All AC voltage ranges are specified from 1 % of range to 100 % of range. 
² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
 
³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.

DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function
Range ¹
Resolution
Accuracy
mV
600.0 mV
0.1 mV
0.09 % + 2
V
6.000 V
0.001 V
0.09 % + 2
60.00 V
0.01 V
600.0 V
0.1 V
1000 V
1 V
0.15 % + 2
)))
600 Ω
1 Ω
Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
600.0 Ω
0.1 Ω
0.5 % + 2
6.000 kΩ
0.001 kΩ
0.5 % + 1
60.00 kΩ
0.01 kΩ
60.00 kΩ
0.1 kΩ
600.0 kΩ
0.001 MΩ
50.00 MΩ
0.01 MΩ
1.5 % + 3
Diode test
2.000 V
0.001 V
1 % + 2
µF
1000 nF
1 nF
1.2 % + 2
10.00 μF
0.01 μF
100.0 μF
0.1 μF
9999 μF ¹
1 μF
10 %
¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.

AC and DC Current
Function
Range ¹
Resolution
Accuracy
mA AC 
(45 Hz to 1 kHz)
60.00 mA
0.01 mA
1.5 % + 3
400.0 mA ³
0.1 mA
mA DC ²
60.00 mA
0.01 mA
0.5 % + 3
400.0 mA
0.1 mA
¹ All AC current ranges are specified from 5 % of range to 100 % of range. 
² Input burden voltage (typical): 400 mA input 2 mV/mA.
 
³ 400.0 mA accuracy specified up to 600 mA overload.

Frequency
Range ¹
Resolution
Accuracy
99.99 Hz
0.01 Hz
0.1 % + 1
999.9 Hz
0.1 Hz
9.999 kHz
0.001 kHz
99.99 kHz
0.01 kHz
¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.

Input Characteristics
Function
Overload 
Protection
Input Impedance 
(nominal)
Common Mode Rejection Ratio (1 kΩ unbalance)
Normal Mode Rejection
1100 V RMS
> 10 MΩ < 100 pF
> 120 dB at DC, 50 Hz or 60 Hz
> 60 dB at 50 Hz or 60 Hz
1100 V RMS
> 10 MΩ < 100 pF
> 60 dB, DC to 60 Hz

1100 V RMS
> 10 MΩ < 100 pF
> 120 dB at DC, 50 Hz or 60 Hz
> 60 dB at 50 Hz or 60 Hz
Open circuit test voltage
Full scale
Typical short circuit current
To 6 MΩ
50 MΩ
1100 V RMS
< 2.7 V DC
< 0.7 V DC
< 0.9 V DC
< 350 mA
1100 V RMS
< 2.7 V DC
2.000 V DC
< 1.1 mA

Function
Overload Protection
Overload
mA
Fused, 44/100 A, 1000 V FAST Fuse
600 mA overload for 2 minutes maximum, 10 minutes rest minimum

MIN/MAX Recording
Function
Accuracy
DC functions
The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration
AC functions
The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration

General Specifications
Maximum voltage between any terminal and earth ground
1000 V DC or AC RMS
Ω fuse protection from A inputs
0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)
Update rate: 4/sec 
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery type
Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life
300 hours minimum
Temperature
Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C
Relative humidity
0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C)
Altitude
Operating: 2,000 m 
Storage: 12,000 m
Temperature coefficient
0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Wireless frequency
2.4 GHz ISM Band 20 meter range
Size (H x W x L)
4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight
340 g (12 oz)
Safety standards
US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
CE European: IEC/EN 61010-1:2010
Electromagnetic compatibility 
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating
IP54