FLUKE – Đồng hồ điện vạn năng kỹ thuật số không
dây Fluke CNX 3000
Model:
Fluke CNX 3000
Hãng
sản xuất: FLUKE – MỸ
Tính năng Đồng hồ điện
vạn năng kỹ thuật số không dây Fluke CNX 3000:
The CNX 3000 Wireless Multimeter has all the
essentials for convenient test and measurement troubleshooting.
- AC and DC voltage measurements to 1000V
- AC and DC current with 0.01 mA resolution
- Continuity, resistance, diode test, capacitance
and frequency measurements
- MIN/MAX Recording
- CAT III 1000 V, Cat IV 600 V; IP54
Plus, the CNX wireless enabled modules
measure AC voltage, AC current and temperature, which display on the
CNX Wireless Multimeter. Choose a standard clamp or flexible clamp to
measure AC current. Mix and match modules to suit your unique measurement
needs. Read the primary measurement on the main display, and up to three
modules at any one time. Modules are available separately or as part of CNX
kits.
Thông số kỹ thuật Đồng hồ điện vạn năng kỹ thuật số
không dây Fluke CNX 3000:
For all specifications: accuracy is specified for one
year after calibration, at operating temperatures of 18 °C to 28 °C, with
relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([
% of Reading ] + [ Number of least significant digits ]).
Detailed Specifications
|
|||
AC Voltage
|
|||
Range ¹
|
Resolution
|
Accuracy ² ³
|
|
45 Hz to 500 Hz
|
500 Hz to 1 kHz
|
||
600.0 mV
|
0.1 mV
|
1.0 % + 3
|
2.0 % + 3
|
6.000 V
|
0.001 V
|
||
60.00 V
|
0.01 V
|
||
600.0 V
|
0.1 V
|
||
1000 V
|
1 V
|
||
¹ All AC voltage ranges are specified from 1 % of range to 100 % of
range.
² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. ³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3. |
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
|
|||
Function
|
Range ¹
|
Resolution
|
Accuracy
|
mV
|
600.0 mV
|
0.1 mV
|
0.09 % + 2
|
V
|
6.000 V
|
0.001 V
|
0.09 % + 2
|
60.00 V
|
0.01 V
|
||
600.0 V
|
0.1 V
|
||
1000 V
|
1 V
|
0.15 % + 2
|
|
)))
|
600 Ω
|
1 Ω
|
Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or
longer.
|
Ω
|
600.0 Ω
|
0.1 Ω
|
0.5 % + 2
|
6.000 kΩ
|
0.001 kΩ
|
0.5 % + 1
|
|
60.00 kΩ
|
0.01 kΩ
|
||
60.00 kΩ
|
0.1 kΩ
|
||
600.0 kΩ
|
0.001 MΩ
|
||
50.00 MΩ
|
0.01 MΩ
|
1.5 % + 3
|
|
Diode test
|
2.000 V
|
0.001 V
|
1 % + 2
|
µF
|
1000 nF
|
1 nF
|
1.2 % + 2
|
10.00 μF
|
0.01 μF
|
||
100.0 μF
|
0.1 μF
|
||
9999 μF ¹
|
1 μF
|
10 %
|
|
¹ In the 9999 μF range for measurements to 1000 μF,
the measurement accuracy is 1.2 % + 2.
|
AC and DC Current
|
|||
Function
|
Range ¹
|
Resolution
|
Accuracy
|
mA AC
(45 Hz to 1 kHz) |
60.00 mA
|
0.01 mA
|
1.5 % + 3
|
400.0 mA ³
|
0.1 mA
|
||
mA DC ²
|
60.00 mA
|
0.01 mA
|
0.5 % + 3
|
400.0 mA
|
0.1 mA
|
||
¹ All AC current ranges are specified from 5 % of range to 100 % of
range.
² Input burden voltage (typical): 400 mA input 2 mV/mA. ³ 400.0 mA accuracy specified up to 600 mA overload. |
Frequency
|
|||
Range ¹
|
Resolution
|
Accuracy
|
|
99.99 Hz
|
0.01 Hz
|
0.1 % + 1
|
|
999.9 Hz
|
0.1 Hz
|
||
9.999 kHz
|
0.001 kHz
|
||
99.99 kHz
|
0.01 kHz
|
||
¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in
amps.
|
Input Characteristics
|
|||||
Function
|
Overload
Protection |
Input Impedance
(nominal) |
Common Mode Rejection Ratio (1 kΩ
unbalance)
|
Normal Mode Rejection
|
|
![]() |
1100 V RMS
|
> 10 MΩ < 100 pF
|
> 120 dB at DC, 50 Hz or 60 Hz
|
> 60 dB at 50 Hz or 60 Hz
|
|
![]() |
1100 V RMS
|
> 10 MΩ < 100 pF
|
> 60 dB, DC to 60 Hz
|
|
|
![]() |
1100 V RMS
|
> 10 MΩ < 100 pF
|
> 120 dB at DC, 50 Hz or 60 Hz
|
> 60 dB at 50 Hz or 60 Hz
|
|
Open circuit test voltage
|
Full scale
|
Typical short circuit current
|
|||
To 6 MΩ
|
50 MΩ
|
||||
![]() |
1100 V RMS
|
< 2.7 V DC
|
< 0.7 V DC
|
< 0.9 V DC
|
< 350 mA
|
![]() |
1100 V RMS
|
< 2.7 V DC
|
2.000 V DC
|
< 1.1 mA
|
Function
|
Overload Protection
|
Overload
|
mA
|
Fused, 44/100 A, 1000 V FAST Fuse
|
600 mA overload for 2 minutes maximum, 10 minutes rest minimum
|
MIN/MAX Recording
|
|
Function
|
Accuracy
|
DC functions
|
The specified accuracy of the measurement function ± 12 counts for
changes > 350 mS in duration
|
AC functions
|
The specified accuracy of the measurement function ± 40 counts for
changes > 900 mS in duration
|
General Specifications
|
|
Maximum voltage between any terminal and earth ground
|
1000 V DC or AC RMS
|
Ω fuse protection from A inputs
|
0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
|
Display (LCD)
|
Update rate: 4/sec
Volts, amps, ohms: 6000 counts Frequency: 10,000 counts Capacitance: 1,000 counts |
Battery type
|
Three AA Alkaline batteries, NEDA 15A IEC LR6
|
Battery life
|
300 hours minimum
|
Temperature
|
Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C
|
Relative humidity
|
0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C) 0 % to 45 % (40 °C to 50 °C) |
Altitude
|
Operating: 2,000 m
Storage: 12,000 m |
Temperature coefficient
|
0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
|
Wireless frequency
|
2.4 GHz ISM Band 20 meter range
|
Size (H x W x L)
|
4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
|
Weight
|
340 g (12 oz)
|
Safety standards
|
US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition CE European: IEC/EN 61010-1:2010 |
Electromagnetic compatibility
EMI, RFI, EMC, RF |
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : T68-FWCS IC:6627A-FWCS |
Ingress Protection (IP) rating
|
IP54
|