Thứ Bảy, 26 tháng 9, 2015

Bơm lấy mẫu khí cá nhân_50 ml/ phút ÷ 12 lít/phút Model: Escort ELF

Bơm lấy mẫu khí cá nhân_50 ml/ phút ÷ 12 lít/phút
Model: Escort ELF
Code: 805558
Hãng sản xuất: Zefon Escort – Anh

Kết quả hình ảnh cho Escort ELF
-          Escort ELF air sampling pumps feature a state of the art electronic laminar flow sensor to provide a constant flow control with ± 2.5% regulation of flow rate (from 1-3 lpm) with automatic compensation for changes in battery voltage, temperature, altitude, and sample load. An internal secondary standard calibrates the pump continuously and needs to checked against a primary standard only once per month (or every 200 hours for coal mine dust sampling).
Features:
-          Patented electronic laminar flow control.
-          Internal secondary standard calibrates the pump continuously, maintaining OSHA compliance.
-          Check against a primary standard only once a month or every 200 hours for coal mine dust sampling.
-          Inlet filter traps moisture and particular matter.
-          Stainless steel-filled plastic case provides EMI/RFI protection.
-          Rated IP66 for resistance to water and dust ingress.
-          Exceptionally quiet operation.
-          Flow-Fault Indicator shows any sample inlet blockage.
-          Run/Hold feature allows “time out” during sampling process.
-          Elapsed time readout and low-battery warning.
-          Low flow and dual tube sampling available with Gemini Twin-Port Sampler.
-          2 Year Warranty.
Approvals:
-          NIOSH certified for coal mine dust sampling (TC-74-030)
-          MSHA certified as intrinsically safe for underground use (Approval # 2G-3924-1).
-          UL approved as intrinsically safe for use in hazardous locations, Class I, Groups A, B, C, D; Class II, Groups E, F and G; Class III, Division I locations.
-          ATEX Approved models available. Contact Zefon or your Zefon distributor for details.
Specifications:
Operating Flow Control
Volumetric flow rate held within ± 2.5% of set-point over the 1-to-3 lpm operating range (± 5% to 0.5 lpm), with automatic compensation for battery voltage, altitude, temperature and sample load changes.
Flow Rate
Flow rate adjustable between 0.5 and 3 lpm; lower flow rates attainable (to 1 mlpm) with optional Gemini Twin-Port Sampling accessory.
Flow Indication
Liquid Crystal Display provides 0.01 lpm resolution.
Operating Range
30 inches of water load up to 2 lpm and 10 inches up to 3 lpm.
Flow Blockage Detection
Flow-Fault LED comes on immediately when block is detected. Pump shuts down within 90 seconds if block is not cleared.
Elapsed Time Readout
To 999 minutes in increments of 1 minute. Holds the last reading after either fl ow blockage or low battery shutdown and when pump is off or in hold mode.
Operating Time
Varies with flow rate and sampling device loading.
Operating Temperature Limits
32°-113°F (0°-45°C)
Physical Weight
23 oz. (652 gm), with battery pack.
Dimensions
2.25” D x 4.25” H x 4” W
(5.7 cm x 10.8 cm x 10.2 cm), with battery pack.
Power Supply
4.8-volt battery pack of four NiMH cells. (Units Mfg before Oct 2011 contain NiCd cells) 
Battery Pack Capacity
2.8 amp hours (NiMH version), 2.4 amp hours (NiCD version)
Battery Pack Recharge Time
14-16 hours (overnight) with Omega™ Charger.
Typical Battery Pack Life
300 or more charging cycles

Không có nhận xét nào: