Thứ Bảy, 26 tháng 9, 2015

Bơm lấy mẫu khí cá nhân_LCD: 0.8 – 5 LPM Model: RAD-Pro 5

Bơm lấy mẫu khí cá nhân_LCD: 0.8 – 5 LPM
Model: RAD-Pro 5
Hãng sản xuất: Radeco – Mỹ
Xuất xứ: Mỹ                       
                                  Kết quả hình ảnh cho RAD-Pro 5

-          The RADeCO RAD-Pro 5 is an industry leader in back-pressure performance, reliability and ease-of-use. This pump offers flow rates up to 5 LPM respectively. And thanks to several advanced features, this pump overcomes the main causes of sampling errors – saving you time and money. The air flow display holds calibration for 30 days, even with atmospheric changes. While RADeCO air sampling pumps are known for their strength, the back-pressure capabilities of the RAD-Pro 5 are the highest in the industry for any personal sampling pump.
-          With the RAD-Pro 5 there is less risk of lost samples due to battery failure. It incorporates a nickel-metal hydride (NiMH) battery which, unlike a NiCd battery,doesn’t suffer from "memory" problems. So there’s no hidden loss of battery capacity, no shorter-than-expected run time and no need for special battery maintenance. You use our standard charger and get the same, highly predictable life, charge after charge.
-          When the display indicates a "full" battery, that’s exactly what the pump delivers. Plus, the indicator more accurately displays remaining life throughout the sampling period. You get faster charging too. The NiMH battery fully charges in just five hours. And you won’t be hampered with special storage or disposal requirements, since the NiMH battery is friendly to the environment.
Feature
RAD-Pro 5
Flow Rate, Max
5 Liters Per Minute
Flow Rate, with Low Flow Module
20 cc/min - 800 cc/min
Flow Rate, Standard
800 cc/min - 5000 cc/min
Flow Compensation 1000 cc/min
70" H20 back-pressure (17.4 kPa)
2000 cc/min
60" H20 back-pressure (15.0 kPa)
3000 cc/min
50" H20 back-pressure (12.4 kPa)
4000 cc/min
30" H20 back-pressure (7.5 kPa)
5000 cc/min
20" H20 back-pressure (5.0 kPa)
Constant Flow Control
± 5% of set flow at 800-5000 cc/min
Programmable
Yes, four stage
30-Day Calibration
Yes
EN 1232 Compliant
Yes
Live Flow Display
Yes
Charging Time
Fully Charged in 4 Hours
Memory-Free Battery
Yes, NiMH
Four-Button User Interface
Yes, with lock-out feature
Run Time
8 hour minimum
Flow Fault
±5% set flow, fault icon appears; if fault exceeds 30 seconds pump shuts down. Pump will attempt restart every 3 minutes for up to 30 minutes.
LCD Display
Yes; Flow Rate, Total Sample Time, Total Volume Sampled, Charge Status , Program Settings.
Hazardous Approval Ratings
FM: Class I, Division I, Groups A, B, C & D
Class II, Groups E, F & G
Class III, T4
CE: Ex II 1 G, Ex ia IIC T4