Thứ Năm, 14 tháng 1, 2016

FLUKE – Bộ KIT đo khoảng cách bằng Lazer và Đo nhiệt hồng ngoại Fluke 414D/62 MAX + Model: Fluke 414D/62 MAX +

FLUKE – Bộ KIT đo khoảng cách bằng Lazer và Đo nhiệt hồng ngoại Fluke 414D/62 MAX +
Model: Fluke 414D/62 MAX +
Hãng sản xuất: FLUKE – MỸ
                               Kết quả hình ảnh cho Fluke 414D/62 MAX + FLUKE
Tính năng Bộ KIT đo khoảng cách bằng Lazer và Đo nhiệt hồng ngoại Fluke 414D/62 MAX +:

The 414D reduces errors, saves time and money.
  • The most advanced laser technology for distance measurement.
  • Measures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in).
  • Quick calculation of area (square feet/meters) and volume.
  • Pythagoras function indirectly measures height via two other measurements.
  • Stores up to five measurement results.
  • Battery life of 3000 measurements with automatic shut-off feature.

Fluke 62 MAX+. Small in size. Big on toughness.
  • Dust and water-resistant: IP54 rated.
  • Rugged: 3-meter (9.8-foot) drop tested.
  • Ergonomically designed: Completely redesigned for a more natural hand fit.
  • Distance to spot: 12:1.
  • Dual lasers: Identifies area to be measured.
  • Large, backlit display: Makes data easier to read, even in dark areas.

Thông số kỹ thuật Bộ KIT đo khoảng cách bằng Lazer và Đo nhiệt hồng ngoại Fluke 414D/62 MAX +:
Distance Measurement
Typical Measuring Tolerance[1]
± 2.0 mm [3]
Maximum Measuring Tolerance[2]
± 3.0 mm [3]
Range at Leica target plate GZM26
50 m / 165 ft
Typical Range[1]
40 m / 130 ft
Range at unfavorable condition[4]
35 m / 115 ft
Smallest unit displayed
1 mm / 1/16 in
laser point at distances
6 /30 / 60 mm 
(10 / 50 / 100 m)
Tilt measurement
Measuring tolerance to laser beam[5]
No
Measuring tolerance to housing[5]
No
Range
No
General
Laser class
2
Laser type
635 nm, <1 mW
Protection class
IP40
Automatic laser off
After 90 seconds
Automatic power off
after 180 seconds
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03
Up to 3,000 
measurements
Size (H X W X L)
116mm Length
53mm Width
 
33mm Depth
Weight (with batteries)
113 g
Temperature range: Storage Operation
-25 °C to +70°C
(-13 °F to +158 °F)
 

0 °C to +40 °C
 
(32 °F to +104 °F)
Calibration cycle
Not applicable
Maximum altitude
3000 m
Maximum relative humidity
85% at 20 °F to 120°F 
(-7 °C to 50 °C)
Safety
IEC Standard No. 61010-1:2001 
EN60825-1:2007 (Class II)
EMC
EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010
[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C. 
[2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 °C to +50 °C.
[3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
[4] Applies for 100 % target reflectivity, background illumination between 10'000 lux and 30'000 lux.
[5] After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.



Fluke 62 MAX+ Infrared Thermometer

Specifications
Temperature Range
-30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy
±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%)
Fluke 62 MAX+
<300 ms (95% of reading)
Spectral Response
8 to 14 microns
Emissivity
0.10 to 1.00
Optical Resolution
12:1 (calculated at 90% energy)
Display Resolution
0.1 °C (0.2 °F)
Repeatability of Readings
±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power
AA battery
Battery Life
8 hours with laser and backlight on
Physical Specifications
Weight
255 g (8.99 oz)

Size
(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches

Operating Temperature
0 °C to 50 °C (32 °F to 122 °F)

Storage Temperature
-20 °C to 60 °C (-4 °F to 140 °F), (without battery)

Operating Humidity
10 % to 90 % RH non-condensing at 30 °C (86 °F)

Operating Altitude
2000 meters above mean sea level

Storage Altitude
12,000 meters above mean sea level

IP Rating
IP 54 per IEC 60529

Drop Test
3 meters

Vibration and Shock
IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms

EMC
EN 61326-1:2006 EN 61326-2:2006
Standards and Agency Approval
Compliance
 EN/IEC 61010-1: 2001

Laser Safety
FDA and EN 60825-1 Class II

Không có nhận xét nào: