The 414D reduces errors, saves time and
money.
- The most advanced laser technology for distance
measurement.
- Measures up to 50 m (165 ft) with accuracy of 2
mm (0.08 in).
- Quick calculation of area (square feet/meters)
and volume.
- Pythagoras function indirectly measures height
via two other measurements.
- Stores up to five measurement results.
- Battery life of 3000 measurements with automatic
shut-off feature.
Fluke 62 MAX+. Small in size. Big on toughness.
- Dust and water-resistant: IP54 rated.
- Rugged: 3-meter (9.8-foot) drop tested.
- Ergonomically designed: Completely redesigned for
a more natural hand fit.
- Distance to spot: 12:1.
- Dual lasers: Identifies area to be measured.
- Large, backlit display: Makes data easier to
read, even in dark areas.
Thông số kỹ thuật Bộ KIT đo khoảng cách bằng Lazer và Đo
nhiệt hồng ngoại Fluke 414D/62 MAX +:
Distance Measurement
|
||
Typical Measuring Tolerance[1]
|
± 2.0 mm [3]
|
|
Maximum Measuring Tolerance[2]
|
± 3.0 mm [3]
|
|
Range at Leica target plate GZM26
|
50 m / 165 ft
|
|
Typical Range[1]
|
40 m / 130 ft
|
|
Range at unfavorable condition[4]
|
35 m / 115 ft
|
|
Smallest unit displayed
|
1 mm / 1/16 in
|
|
∅
laser point at distances
|
6 /30 / 60 mm
(10 / 50 / 100 m) |
|
Tilt measurement
|
||
Measuring tolerance to laser beam[5]
|
No
|
|
Measuring tolerance to housing[5]
|
No
|
|
Range
|
No
|
|
General
|
||
Laser class
|
2
|
|
Laser type
|
635 nm, <1 mW
|
|
Protection class
|
IP40
|
|
Automatic laser off
|
After 90 seconds
|
|
Automatic power off
|
after 180 seconds
|
|
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03
|
Up to 3,000
measurements |
|
Size (H X W X L)
|
116mm Length
53mm Width 33mm Depth |
|
Weight (with batteries)
|
113 g
|
|
Temperature range: Storage Operation
|
-25 °C to +70°C
(-13 °F to +158 °F) 0 °C to +40 °C (32 °F to +104 °F) |
|
Calibration cycle
|
Not applicable
|
|
Maximum altitude
|
3000 m
|
|
Maximum relative humidity
|
85% at 20 °F to 120°F
(-7 °C to 50 °C) |
|
Safety
|
IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II) |
|
EMC
|
EN 55022:2010
EN 61000-4-3:2010 EN 61000-4-8:2010 |
|
[1] Applies for 100 % target reflectivity (white painted wall), low
background illumination, 25 °C.
[2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 °C to +50 °C. [3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m. [4] Applies for 100 % target reflectivity, background illumination between 10'000 lux and 30'000 lux. [5] After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°. |
||
Fluke 62 MAX+ Infrared
Thermometer
Specifications
|
||
Temperature Range
|
-30 °C to 650 °C (-22 °F to 1202 °F)
|
|
Accuracy
|
±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0 -30 °C to -10 °C: ±3.0 |
|
Response Time (95%)
|
Fluke 62 MAX+
|
<300 ms (95% of reading)
|
Spectral Response
|
8 to 14 microns
|
|
Emissivity
|
0.10 to 1.00
|
|
Optical Resolution
|
12:1 (calculated at 90% energy)
|
|
Display Resolution
|
0.1 °C (0.2 °F)
|
|
Repeatability of Readings
|
±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
|
|
Power
|
AA battery
|
|
Battery Life
|
8 hours with laser and backlight on
|
|
Physical Specifications
|
Weight
|
255 g (8.99 oz)
|
|
Size
|
(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
|
|
Operating Temperature
|
0 °C to 50 °C (32 °F to 122 °F)
|
|
Storage Temperature
|
-20 °C to 60 °C (-4 °F to 140 °F), (without battery)
|
|
Operating Humidity
|
10 % to 90 % RH non-condensing at 30 °C (86 °F)
|
|
Operating Altitude
|
2000 meters above mean sea level
|
|
Storage Altitude
|
12,000 meters above mean sea level
|
|
IP Rating
|
IP 54 per IEC 60529
|
|
Drop Test
|
3 meters
|
|
Vibration and Shock
|
IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
|
|
EMC
|
EN 61326-1:2006 EN 61326-2:2006
|
Standards and Agency Approval
|
Compliance
|
EN/IEC 61010-1: 2001
|
|
Laser Safety
|
FDA and EN 60825-1 Class II
|