FLUKE - Máy phân tích nguồn 3 pha Fluke 1740
Model: Fluke 1740
Hãng sản xuất: FLUKE – MỸ
Tính năng Máy phân tích chất lượng điện năng Fluke 1740:
- Plug and play: Setup in minutes with automatic current probe detection and powering
 
- Installs inside the cabinet: Compact, fully-insulated housing and accessories fit easily in tight spaces next to live power
 
- Determines the root cause: Included PQ Log software quickly analyzes trends, creates statistical summaries, and generates detailed graphs and tables
 
- Monitors power for the long-term: Data can be downloaded during recording without interruption
 
- Measure voltage with premium accuracy: IEC61000-4-30 Class-A compliant voltage accuracy (0.1%)
 
- Quickly validate quality of power: Assess power quality according to EN50160 power quality standard with statistical overview
 
- Rugged and reliable: Designed for everyday field use with no moving parts and durable insulated case with two year warranty
 
Thông số kỹ thuật Máy phân tích chất lượng điện năng Fluke 1740:
General Data 
 | 
Intrinsic error 
 | 
 | 
 Refers to the reference conditions and is guaranteed for two years 
 |  
 
 | 
Warranty 
 | 
 | 
Recalibration interval 
 | 
 | 
Quality system 
 | 
 | 
 developed, designed, and manufactured according to DIN ISO 9001 
 |  
 
 | 
Reference conditions 
 | 
 | 
 23 °C ± 2 K; 74 °F ± 2 K , Vm=230 V ± 10%, 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 
 |  
Phase sequence: 
 | 
 L1, L2, L3 
 |  
Interval length: 
 | 
 10 minutes 
 |  
Wye connection: 
 | 
 (L1, L2, L3 to N) 
 |  
Power supply: 
 | 
 88 V ... 265 V AC 
 |  
 
 | 
Environment conditions 
 | 
Working temp. range: 
 | 
 -10 °C to 55°C; 14 °F to 131°F 
 |  
Operating temp. range: 
 | 
 0 °C to 35°C; 32 °F to 95°F 
 |  
Storage temp. range: 
 | 
 -20 °C to 60°C; -4 °F to 140°F 
 |  
Reference temp. range: 
 | 
 23 °C ± 2 K; 74 °F ± 2 K 
 |  
Relative humidity: 
 | 
 Fluke 1745: Class B2 acc. IEC 60654-1 Fluke 1744/43: Class C2 acc. IEC 60654-1 
 |  
 
 | 
Housing 
 | 
 | 
 robust, fully insulated housing and accessories 
 |  
 
 | 
Protection type 
 | 
Fluke 1745: 
 | 
 IP50 as per EN 60529 
 |  
Fluke 1744/1743: 
 | 
 IP65 as per EN 60529 
 |  
 
 | 
Safety 
 | 
 | 
 IEC/EN 61010-1 600 V CAT III, 300 V CAT IV, pollution degree 2, double insulation 
 |  
 
 | 
Type test voltage 
 | 
 | 
 5.2 kV rms, 50 Hz / 60 Hz, 5 s 
 |  
 
 | 
EMC 
 | 
Emission: 
 | 
 IEC/EN 61326-1, EN55022 
 |  
Immunity: 
 | 
 IEC/EN 61326-1 
 |  
 
 | 
Voltage and Current Measurement 
 | 
Input voltage 
 | 
Input range VIP-N: 
 | 
 max 480 V AC 
 |  
Input range VIP-P: 
 | 
 max 830 V AC 
 |  
Max. overload voltage: 
 | 
 1.2 VI 
 |  
Input range selection: 
 | 
 By job programming 
 |  
Connections: 
 | 
 P-P or P-N, 1- or 3-phase 
 |  
Nominal voltage VN: 
 | 
 <= 999 kV with PTs and ratio 
 |  
Input resistance: 
 | 
 App. 820 kΩ per chan. Lx-N Single phase (L1 or A, L2 or B, L3 or C connected): app. 300 kΩ 
 |  
Intrinsic uncenrtainty: 
 | 
 0.1 % of VI 
 |  
Voltage transformer: 
 | 
 Ratio: <999 kV / VI 
 |  
Ration selection: 
 | 
 By job programming 
 |  
 
 | 
Current input with Flexi Set 
 | 
Input ranges II L1 or A, L2 or B, L3 or C, N: 
 | 
 15 A / 150 A / 1500 A / 3000 A ac 
 |  
Measuring range: 
 | 
 0.75 A … 3000 A ac 
 |  
Intrinsic uncertainty: 
 | 
 < 2 % of II 
 |  
Position influence: 
 | 
 Max. ± 2 % of measured value – for distance conductor to meas. head > 30 mm 
 |  
Stray field influence: 
 | 
 < ± 2 A ac for Iext=500 A ac and distance to measuring head > 200 mm 
 |  
Temperature coefficient: 
 | 
 < 0.05 % / K 
 |  
Current transformer: 
 | 
 Ratio <= 999 kA / II 
 |  
Ratio selection: 
 | 
 By job programming 
 |  
Connection: 
 | 
 3-phase, 3-phase +N, 2 phase L1 or A and L3 or C (2 W-meter-method) 7 pole connector 
 |  
 
 | 
Current input for clamp 
 | 
Input ranges II L1 or A,  L2 or B, L3 or C, N: 
 | 
 0.5 V nominal (for II) 1.4 Vpeak 
 |  
Intrinsic uncertainty: 
 | 
 < 0.3 % of II 
 |  
Max. overload: 
 | 
 10 V ac 
 |  
Input resistance: 
 | 
 App. 8.2 kΩ 
 |  
Current transformer: 
 | 
 Ratio Ω 999 kA / II 
 |  
 
 | 
Power systems 
 | 
 | 
 Delta, 2-Element Delta, Wye, Single Phase, Split Single Phase 
 |  
 
 | 
Logger 
 | 
Power supply 
 | 
Functional Range: 
 | 
 88 V to 660 V absolute, 50 Hz / 60 Hz 100 V to 350 V dc Internal fuse: 630 mA T 
 |  
Power consumption: 
 | 
 5 Watts 
 |  
Ride through: 
 | 
 Fluke 1745: Internal battery for typ. > 5 hours ride through with intelligent power management Fluke 1743/44: 3 sec Capacitor 
 |  
Fuse: 
 | 
 Power supply fuse can be replaced in service facility only. Supply can be connected in parallel to measuring inputs (up to 660 V) 
 |  
 
 | 
Display, indicators 
 | 
 | 
 LEDs for status and voltage levels Fluke 1745: LC-display with backlight for voltage, current, active power, phase sequence. 
 |  
 
 | 
Memory 
 | 
 | 
 Capacity 8 MB Flash-EPROM 
 |  
Intervals: 
 | 
 A function > 12000 intervals for > 85 days with 10 min intervals P function > 30000 intervals for > 212 days with 10 min intervals 
 |  
Events: 
 | 
 > 13000 
 |  
Memory model: 
 | 
 linear, circular 
 |  
 
 | 
Interface 
 | 
 | 
 RS 232, 9600...115 000 Baud, automatic Baud rate selection, 3-wire communication 
 |  
 
 | 
Dimensions 
 | 
Fluke 1745: 
 | 
 282 mm x 216 mm x 74 mm (115in x 88in x 33in) 
 |  
Fluke 1743/1744: 
 | 
 170 mm x 125 mm x 55 mm (69in x 51in x 22in) 
 |  
 
 | 
Weight 
 | 
Fluke 1745: 
 | 
 approx. 3 kg 
 |  
Fluke 1744/1743: 
 | 
 approx. 2 kg 
 |  
 
 | 
Measurement 
 | 
A/D converter: 
 | 
 16 bit, sample rate: 10.24 kHz 
 |  
Anti-aliasing filter: 
 | 
 FIR-Filter, fc =4.9 kHz 
 |  
Frequency response: 
 | 
 Uncertainty < 1 % of Vm for 40 Hz to 2500 Hz 
 |  
Interval length: 
 | 
 1, 3, 5, 10, 30 s, 1, 5, 10, 15, 60 minutes 
 |  
Averaging time for Min/max values: 
 | 
 ½, 1 mains period, 200 ms,1 , 3 , 5 s 
 |  
Time base: 
 | 
 Resolution: 10 ms (at 50 Hz), deviation: 2s/day at 23 °C; 74 °F ± 2 K 
 |  
 
 | 
 