Thứ Năm, 14 tháng 1, 2016

FLUKE - Ghi chất lượng điện áp một pha FLuke VR1710 Model: Fluke VR1710

FLUKE - Ghi chất lượng điện áp một pha FLuke VR1710
Model: Fluke VR1710
Hãng sản xuất: FLUKE – MỸ
                                 Kết quả hình ảnh cho Fluke VR1710 FLUKE
Tính năng Máy ghi chất lượng điện ba pha Fluke VR1710:
  • Fast and easy recording of voltage trends, dropouts, and power quality – Easily pinpoint the root cause of single phase voltage problems
  • Extremely easy to use – Plug directly into the mains power socket and capture data
  • Continuous recording of all values with no gaps – Save testing time by getting the whole picture with one instrument that records both events and voltage
  • Clear graphical summary of data and quick overview of key power quality parameters – Take the guesswork out of diagnosing voltage quality problems
  • Min, Max, and Average RMS values (1/4 cycle) with time stamp – Quickly see what happened and when
  • Actual transient display (>100 μs) with time stamp – Identify power quality issues quickly with included graphical software
  • Flicker recording to EN 61000-4-15, individual harmonic and THD values with trends – Easily identify if the problem is power quality or equipment related
  • Statistical analysis of single phase voltage events - Reduces analysis time by tracking event quantities and magnitudes
  • Includes PowerLog software package for quick download, analysis, and automatic reporting – Save time by generating power quality reports automatically with pre-set templates
Thông số kỹ thuật Máy ghi chất lượng điện ba pha Fluke VR1710:
General specifications
Operating voltage
 70 V to 300 V
Min/Max/Avg RMS value
 Resolution 0.125 V
Number of events
 175,000
Dips/Interruptions
 Yes
Time resolution
 5 ms
Voltage resolution
 0.125 V
Over-voltages
 Yes
Frequency
 Yes
Harmonics measurement
 EN 61000-4-7 (up to 32nd)
Flicker measurement
 EN 61000-4-15
Number of recording channels
 1 Phase to Neutral
2 Phase/Neutral to Ground
Recording time
 1 day to 339 days depending on average time from 1 second to 20 minutes
Transients
 Yes
Frequency range
 50 Hz ± 1 Hz and 60 Hz ± 1 Hz
Safety category rating
 CAT II 300 V