Thứ Năm, 14 tháng 1, 2016

FLUKE – Máy hiệu chuẩn áp suất Fluke 719Pro-30G Model: Fluke 719Pro-30G

FLUKE – Máy hiệu chuẩn áp suất Fluke 719Pro-30G
Model: Fluke 719Pro-30G
Hãng sản xuất: FLUKE – MỸ
                              Kết quả hình ảnh cho Fluke 719Pro-30G  FLUKE
Tính năng Máy hiệu chuẩn áp suất Fluke 719Pro-30G:
  • Unique integrated electric pump for one handed pressure calibration
  • Test pressure switches easily with easy-to-use switch test function
  • Precision pressure adjust vernier for easy and accurate pressure calibration
  • Ideal accuracy and performance (0.025 %) for reference class transmitter calibration
  • 30 PSI, 150 PSI and 300 PSI pressure ranges
  • Programmable pressure calibrator pump limit:
    • Eliminates over-pressurization
    • Allows the user to program target pressures for pumping
  • Extended pressure measurement range with any of 29 700Pxx Pressure Modules
  • Pump cleanout ports reduce pump failures from moisture and fluid damage
  • Fluid trap included with the unit to mitigate chance of fluid damage in at-risk applications
  • Precision temperature measurement with optional RTD probe
Thông số kỹ thuật Máy hiệu chuẩn áp suất Fluke 719Pro-30G:
Specifications
Pressure Measurement
Range
-12 to 30 PSI /-0.8 to 2 bar
Resolution
0.001 PSI, 0.0001 bar
Accuracy (1 year)
± 0.025 % of full scale, 6 months ± 0.035 % of full scale, 
1 year Dry Air and non-corrosive gas only
Temperature effect (all ranges)
Add ± 0.002 % F.S./°C for temps outside of 15 °C to 35 °C 
No effect on accuracy on all functions from 15 °C to 35 °C
Function
Range
Resolution
Accuracy (1 year)
Comment
mA dc (simulation and measurement)
0-24 mA dc
0.001 mA
± 0.015 % of reading ± 2 counts
1000 ohm maximum load in mA source, 26 V dc maximum voltage in mA simulate
Volts dc (measurement only)
30 V dc
0.001 V
± 0.015 % of reading ± 2 counts
No AC voltage measurement, do not exceed 30 V dc
Temperature (measurement only, Pt100 RTD)
-50 to 150 °C (-50 °F to 302 °F)
0.01 °C
0.01 °F
Temperature ± 0.1 °C (0.2 °F)
± 0.25 °C (± 0.45 °F) combined uncertainty when using 720 RTD probe (optional accessory)
Loop power supply
24 V dc
N/A
24 mA at 24 V
Temperature effect (all functions)


Add ± 0.002 % F.S./°C for temps outside of 15 °C to 35 °C
No effect on accuracy on all functions from 15 °C to 35 °C
Environmental
Operating temperature
-10 °C to +50 °C
Storage temperature (with batteries)
Per battery manufacturer's specification within storage specification below
Storage temperature (without batteries)
-20 °C to +60 °C
Power Requirements
Battery
Eight (8) standard Alkaline AA batteries
Battery life
300 pump cycles to 150 PSI minimum; 1000 pump cycles to 30 PSI; 100 pump cycles to 300 PSI minimum
Physical
Dimensions (HxWxD)
24.13 cm x 11.18 cm x 7 cm (9.5 in x 4.4 in x 2.8 in)
Weight
With holster 1.2 kg (2.5 lb)
Connections
Pressure
1/8 inch female NPT
Electrical
Standard banana jacks
RTD
4 pin miniature circular
External module
6 pin miniature circular
Engineering Units (Configurable)
psi, bar, mbar, kPa, kgcm2, cmH2O@4 °C, cmH2O@20 °C, mH2O@4 °C, mH2O@20 °C, inH2O@4 °C, inH2O@20 °C, inH2O@60 °F, mmHg@0 °C, inHg@0 °C, ftH2O@4 °C, ftH2O@20 °C, ftH2O@60 °F

Không có nhận xét nào: