FLUKE – Máy kiểm tra dụng cụ cầm tay Fluke 6000 Series Portable Appliance Testers
Model: Fluke 6000 Series Portable Appliance Testers
Hãng sản xuất: FLUKE – MỸ
Tính năng Máy kiểm tra dụng cụ cầm tay Fluke 6000 Series Portable Appliance Testers:
Fluke simplifies portable appliance testing
6200
- Dedicated key for each test for ‘one-touch’ testing
 
- Pre-set pass/fail levels to save time
 
- Large backlit display for easy reading
 
- Single mains socket for appliance connection
 
- Separate IEC socket for easy mains/extension lead testing
 
- Detachable test leads for quick field replacement
 
- Integral carrying handle
 
 
 | 
6500 
As 6200 but also with: 
- Integral QWERTY keyboard for rapid data entry
 
- Additional Compact Flash memory card capability for back-up data storage and transfer to PC
 
- Large backlit graphics display
 
- Pre-set, auto-test sequences for user convenience
 
- Integral site, location and description codes for faster data processing
 
- Memory review facility for more on-site control
 
 
 | 
Tính năng Máy kiểm tra dụng cụ cầm tay Fluke 6000 Series Portable Appliance Testers:
Test Specifications 
 | 
  
 | 
 | 
 The accuracy specification for the display range is defined as ± (%reading + digit counts) at 23 °C ± 5 °C, ≤ 75 % RH. Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy specification) per °C. 
 |  
 | 
 The measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997 , EN61557-4: 1997. 
 |  
 
 | 
Power-on Test 
 | 
 | 
 The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency. 
 |  
Display range: 
 | 
 90 V to 264 V 
 |  
Accuracy at 50 Hz: 
 | 
 ± (2% + 3 counts) 
 |  
Resolution: 
 | 
 0.1 V (1 V - model 6200) 
 |  
Input impedance 
 | 
 > 1 MΩ // 2.2 nF 
 |  
Maximum input mains voltage: 
 | 
 300 V 
 |  
 
 | 
Earth Bond Test (Rpe) 
 | 
Display range: 
 | 
 0 to 19.99 Ω 
 |  
Accuracy (after Bond Test zeroing): 
 | 
 ± (2.5% + 4 counts) 
 |  
Resolution: 
 | 
 0.01 Ω 
 |  
Test current: 
 | 
 200 mA AC -0% +40% into 1.99 Ω 
 |  
 | 
 25 A AC ± 20% into 25 mΩ at 230 V 
 |  
Open circuit voltage: 
 | 
 > 4 V AC, < 24 V AC 
 |  
Bond test zeroing: 
 | 
 can subtract up to 1.99 Ω 
 |  
 
 | 
Insulation Test (Riso) 
 | 
Display range: 
 | 
 0 to 299 MΩ 
 |  
Accuracy: 
 | 
 ± (5% + 2 counts) from 0.1 to 300 MΩ 
 |  
Resolution: 
 | 
 0.01 MΩ (0 to 19.99 MΩ) 
 |  
 | 
 0.1 MΩ (20 to 199.9 MΩ) 
 |  
 | 
 1 MΩ (200 to 299 MΩ) 
 |  
Test voltage: 
 | 
 500 V DC -0% + 10% at 500 kΩ load 
 |  
Test current: 
 | 
 > 1 mA at 500 kΩ load, < 15 mA at 0 Ω 
 |  
Auto discharge time: 
 | 
 < 0.5 s for 1 μF 
 |  
Max. capacitive load: 
 | 
 operational up to 1 μF 
 |  
 
 | 
Touch Current Test 
 | 
Display range: 
 | 
 0 to 1.99 mA AC 
 |  
Accuracy: 
 | 
 ± (4% + 2 counts) 
 |  
Resolution: 
 | 
 0.01 mA 
 |  
Internal resistance (via probe): 
 | 
 2 kΩ 
 |  
Measuring method: 
 | 
 probe 
 |  
 | 
 The appliance under test is energized at mains potential. 
 |  
 
 | 
Substitute Leakage Current Test 
 | 
Display range: 
 | 
 0 to 19.99 mA AC 
 |  
Accuracy: 
 | 
 ± (2.5% + 3 counts) 
 |  
Resolution: 
 | 
 0.01 mA 
 |  
Test voltage: 
 | 
 35 V AC ± 20% 
 |  
 
 | 
Load/Leakage Test: Load Current 
 | 
Display range: 
 | 
 0 to 13 A 
 |  
Accuracy: 
 | 
 ± (4% + 2 counts) 
 |  
Resolution: 
 | 
 0.1 A 
 |  
 | 
 The appliance under test is energized at mains potential. 
 |  
 
 | 
Load/Leakage Test: Load Power 
 | 
Display range: 
 | 
 0 to 999 VA 
 |  
 | 
 1.0 kVA to 3.2 kVA 
 |  
Accuracy: 
 | 
 ± (5% + 3 counts) 
 |  
Resolution: 
 | 
 1 VA (0 to 999 VA) 
 |  
 | 
 0.1 kVA (1.0 kVA to 3.2 kVA) 
 |  
 | 
 The appliance under test is energized at mains potential. 
 |  
 
 | 
Load/Leakage Test: Leakage Current 
 | 
Display range: 
 | 
 0 to 19.99 mA 
 |  
Accuracy: 
 | 
 ± (4% + 4 counts) 
 |  
Resolution: 
 | 
 0.01 mA 
 |  
 | 
 The appliance under test is energized at mains potential. 
 |  
 
 | 
PELV Test 
 | 
Accuracy at 50 Hz: 
 | 
 ± (2% + 3 counts) 
 |  
Overload protection: 
 | 
 300 Vrms 
 |  
Warning threshold: 
 | 
 25 Vrms 
 |  
 
 | 
Environmental Specifications 
 | 
Operating Temperature 
 | 
 | 
Relative Humidity 
 | 
 | 
 non condensing < 10 °C 
 |  
 | 
 95% from 10 to 30 °C 
 |  
 | 
 75% from 30 to 40 °C 
 |  
 
 | 
Safety Specifications 
 | 
Safety Rating 
 | 
 | 
Mechanical & General Specifications 
 | 
Size 
 | 
 | 
 200 mm (L) x 275 mm (W) x 100 mm (H) 
 |  
 
 | 
Weight 
 | 
 | 
Power Supply 
 | 
 | 
 V + 10 % - 15 %, 50 Hz ± 2 % 
 |  
 
 | 
Power Consumption (Tester) 
 | 
 | 
 13 W typical (idle) 
 |  
 | 
 60 W max. during 25A Bond Test 
 |  
 
 | 
Storage 
 | 
Temperature: 
 | 
 -10 to 60 °C 
 |  
Corrosion: 
 | 
 70 °C @ 95 % RH for 5 days max. 
 |  
 
 | 
Operating Altitude 
 | 
 | 
Sealing 
 | 
 | 
 IP-40 (enclosure), IP-20 (connectors) 
 |  
 
 | 
EMC 
 | 
 | 
 complies with EN61326-1, criteria B 
 |  
 
 | 
EMI Immunity 
 | 
 | 
 
Không có nhận xét nào: