Thứ Năm, 14 tháng 1, 2016

FLUKE – Máy hiện sóng Fluke 120 Series Model: Fluke 120 Series

FLUKE – Máy hiện sóng Fluke 120 Series
Model: Fluke 120 Series
Hãng sản xuất: FLUKE – MỸ
                             Kết quả hình ảnh cho Fluke 120 Series  FLUKE
Tính năng Máy hiện sóng Fluke 120 Series:
ScopeMeter® 120 Series : As simple as one-two-three
  • Dual-input 40 MHz or 20 MHz digital oscilloscope
  • Two 5,000 counts true-RMS digital multimeters
  • Automatic measurements
  • A dual-input TrendPlot™ recorder
  • Connect-and-View™ trigger simplicity for hands-off operation
  • Shielded test leads for oscilloscope, voltage, resistance and continuity measurements
  • 10:1 Voltage Probe included with Fluke 124 and 125 for high frequency measurements
  • Up to 7 hours battery operation
  • 600 V CAT III safety certified
  • Optically-isolated interface for PC connection
  • Rugged, compact case
  • Fluke 125 gives bus health and power measurements

Thông số kỹ thuật Máy hiện sóng Fluke 120 Series:
Specifications
Oscilloscope Bandwidth
Fluke 125:
 40 MHz
Fluke 124:
 40 MHz
Fluke 123:
 20 MHz
Dual input True RMS Meter
 Vdc, Vac, Vac+Vdc, Ohms,Continuity , Diode-test
 Current, °C, °F, Capacitance, dBV, dBM, Crest Factor, Touch Hold and Zeroset
TrendPlot Recording
 Automatic vertical scaling and time compression.
 Display the actual, MIN, MAX and AVG reading.
Cursors
Fluke 125/124:
 ∆T, 1/∆T, V, ∆V, rise- and fall time
Real-time sample rate
 25 MS/s
Equivalent sampling rate
 up to 2.5 GS/s (125, 124) or 1.25 GS/s (123).
Inputs and digitizers
  2
Timebase range
Fluke 125/124:
 20 ns - 1 min/div
Fluke 123:
 10 ns - 1 min/div
Input sensitivity
 5 mV - 500 V/div
Trigger types
 Connect-and-View™, Free Run, Single Shot, Edge, Video, External
Glitch capture
 40 ns
Scope measurements
 Automatic measurements: 26 (all instruments) On top, Fluke 125 has additional measurement functions for Power (W), VA, VAR and Power Factor (PF) for single phase and balanced-three-phase (delta) power systems.
Harmonics mode
 Fluke 125 has capbility to analyze the harmonics contents of power signals. See below for details.
Maximum record length
 512 min/max pts per input
Memory
Fluke 125/124:
 20 screens and setups
Fluke 123:
 10 screens and setups
Additional Power measurement capabilities (Fluke 125 only)
Measurement types:
 Watt,
 VA,
 VAR,
 Power Factor (PF)
Power configuration:
 Single phase or balanced three-phase (delta-configuration) mains supply
Voltage measurement
 Channel A; using STL120, voltage probe or direct input
Current measurement
 Channel B, using i400s (included) or other compatible current clamp
Current Clamp or Shunt sensitivity:
 0.1 / 1 / 10 / 100 / 1000 mV/A, 10 mV/mA and 400 mV/A.
Harmonics Mode (Fluke 125 only)

 Converts waveform information into a harmonics display (using FFT processing) which shows the relative amplitudes of the 1st up to the 33rd harmonic
Analyzed waveform:
 Voltage waveform(Ch.A), Current wavefrom (Ch.B) or Power (Ch.A x Ch.B), automatically generated.
Harmonics Frequency range:
 DC up to 33rd harmonic (for fundamental up to 60 Hz);
 DC up to 24th harmonic (for fundamental up to 400 Hz).
Display
 Bargraph showing 1st up to 33rd harmonic and DC; amplitude displayed in % relative to fundamental
Measurements:
 Relative amplitude of individual harmonics;
 THD in %r or %f.
Environmental Specifications
Operating Temperature
 0 ºC to 50 ºC
Storage Temperature
 -20 °C to +60 °C
Operating Altitude
 3,000 m
Safety Specifications
Electrical Safety
 600V CAT III (EN61010-1)
Mechanical & General Specifications
Size
 232 x 115 x 50 mm
Weight
 1.2 kg
Warranty
 3-years on main instrument, 1-year on accessories
Battery Life
 7 hrs using NiMH
RS232/USB Interface
 Optically isolated via optional PM9080 or OC4USB for interfacing to Printer or PC

Không có nhận xét nào: