Thứ Năm, 14 tháng 1, 2016

FLUKE – Máy đo khoảng cách bằng Lazer Fluke 419D Model: Fluke 419D

FLUKE – Máy đo khoảng cách bằng Lazer Fluke 419D
Model: Fluke 419D
Hãng sản xuất: FLUKE – MỸ

                              Kết quả hình ảnh cho Fluke 419D FLUKE
Tính năng Máy đo khoảng cách bằng Lazer Fluke 419D:

The 419D distance meters offer these enhanced features: 

  • Measure up to 80 m (260 ft)
  • Higher accuracy: +/-1 mm (0.04 in)
  • View more data with backlit, three-line display
  • Full Pythagoras function for height measurements
  • Storage of 20 complete displays for quick recall
  • Audible keypad feedback
  • Minimum/Maximum function
  • Tripod mode for mounting meter on a tripod when measuring long distances
  • Stake Out feature helps you mark out defined lengths such as when constructing wooden frames
  • Automated End-piece Correction for measuring from an edge or corner --a built-in sensor detects the position of this bracket and automatically changes the reference point.
  • Enhanced environmental protection:IP54-rated as dust and water spray resistant
  • Improved battery life of 5000 measurements with auto laser off and auto power off features.
Like all new Fluke laser distance meters, the 419D offers instant, one-button measurement of the distance between two objects plus:
  • Bright laser for easy targeting
  • Quick calculations of area (square feet/meters) and volume
  • Easy-to-use addition and subtraction function
  • Carrying pouch secures to tool belt
All meters offer: 
  • Reduction of estimation errors, saving both time and money
  • The most advanced 2 laser technology for distance measurement
  • Instant measurement with one-button operation
  • Easy addition and subtraction function
  • Quick calculation of area (square footage) and volume
  • Easy addition and subtraction of measurements
  • Minimum/maximum function
  • Improved battery life from automatic shut-off feature
  • Pythagoras calculation for determining distance indirectly from two other measurements
  • Pouch with Fluke logo
  • Three-year warranty
The 424D and 419D additionally offers: 
  • Improved visibility with backlit screen
  • Ability to measure up to 80 m (260 ft) for 419D, 100 m (330 ft) for 424D
  • Tripod mode allows you to mount to a tripod for measuring long distances
  • Stake out function
  • Enhanced Pythagoras calculation for determining distance indirectly from three other measurements
  • Audible keypad feedback
  • Storage of the last twenty measurements for quick recall of distance
  • Strong environmental protection with IP54 (water spray and dust proof) sealing

Thông số kỹ thuật Máy đo khoảng cách bằng Lazer Fluke 419D:


Model
414D
419D
424D

Distance Measurement
Typical Measuring Tolerance[1]
± 2.0 mm [3]
± 1.0 mm [3]
Maximum Measuring Tolerance[2]
± 3.0 mm [3]
± 2.0 mm [3]
Range at Leica target plate GZM26
50 m / 165 ft
80 m / 260 ft
100 m / 330 ft
Typical Range[1]
40 m / 130 ft
80 m  / 260 ft
80 m / 260 ft
Range at unfavorable condition[4]
35 m / 115 ft
60 m / 195 ft
60 m / 195 ft
Smallest unit displayed
1 mm / 1/16 in
6 /30 / 60 mm 
(10 / 50 / 100 m)
laser point at distances
6 /30 / 60 mm 
(10 / 50 / 100 m)
6 /30 / 60 mm 
(10 / 50 / 100 m)
Tilt measurement
Measuring tolerance to laser beam[5]
No
No
± 0.2°
Measuring tolerance to housing[5]
No
No
± 0.2°
Range
No
No
360°
General
Laser class
2
Laser type
635 nm, <1 mW
Protection class
IP40
IP54
Automatic laser off
After 90 seconds
Automatic power off
after 180 seconds
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03
Up to 3,000 
measurements
Up to 5,000 
measurements
Size (H X W X L)
116mm Length
53mm Width
 
33mm Depth
127mm Length 
56mm Width
33mm Depth
127mm Length 
56mm Width
 
33mm Depth
Weight (with batteries)
113 g
153 g
158 g
Temperature range: Storage Operation
-25 °C to +70°C
(-13 °F to +158 °F)
 

0 °C to +40 °C
 
(32 °F to +104 °F)
-25 °C to +70°C 
(-13 °F to +158 °F)
 

-10 °C to +50 °C
 
(14 °F to +122 °F)
Calibration cycle
Not applicable
Not applicable
Tilt and compass
Maximum altitude
3000 m
3000 m
3000 m
Maximum relative humidity
85% at 20 °F to 120°F 
(-7 °C to 50 °C)
85% at 20 °F to 120°F 
(-7 °C to 50 °C)
85% at 20 °F to 120°F 
(-7 °C to 50 °C)
Safety
IEC Standard No. 61010-1:2001 
EN60825-1:2007 (Class II)
EMC
EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010
[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C. 
[2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 °C to +50 °C.
[3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
[4] Applies for 100 % target reflectivity, background illumination between 10'000 lux and 30'000 lux.
[5] After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.