FLUKE – Máy đo lưu lượng không khí Fluke-975 Model: Fluke 975

FLUKE – Máy đo lưu lượng không khí Fluke-975
Model: Fluke 975
Hãng sản xuất: FLUKE – MỸ
                             Kết quả hình ảnh cho Fluke 975  FLUKE
Tính năng Máy đo lưu lượng không khí Fluke-975:
The Fluke 975 offers an unparalleled featureset for HVAC and facilities technicians, helping them work more quickly and accurately, with the ease of use and durability customers expect from a Fluke meter.
  • Simultaneously measures, logs, and displays temperature, humidity, CO2, and CO on a bright, backlit LCD display
  • One-touch air flow and velocity with available probe*
  • Wet bulb and dew point temperature
  • % of outside air calculation
  • CO2 and CO field calibration feature
  • Self-test function at startup
  • Auto-backlight
  • Automatically compensates for barometric pressure changes
  • Min/Max/Average on all measured and calculated readings
  • Multi-language user interface
  • Metric or standard units
  • Audible and visual threshold alarms
  • Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface
  • Keypad lock for security
  • Included FlukeView Forms® software
Thông số kỹ thuật Máy đo lưu lượng không khí Fluke-975:
Measured specifications
Temperature
Range:
 -20 °C to 50 °C (-5 °F to 122 °F)
Display resolution:
 0.1 °C (0.1 °F)
Accuracy:
 ± 0.9 °C/± 1.62°F from 40 °C to 60 °C
± 0.5 °C/± 1.00°F from 5 °C to 40 °C
± 1.1 °C/± 1.98 °F from -20 °C to 5 °C
Relative humidity
Range:
 10 % to 90 % RH, non-condensing
Display Resolution:
 1%
Accuracy:
 ± 2 % RH (10 % RH to 90 % RH)
Air velocity
Range:
 50.0 fpm to 3000 fpm
0.25 m/sec to 15 m/sec
Display Resolution:
 1 fpm (0.005m/sec)
Accuracy:
 ±4 % or 4 fpm*
±4 % or 0.02 m/sec* whichever is greater
*Accuracy specification only valid for velocity readings above 50 fpm.
C0
Range:
 0 to 500 ppm
Display Resolution:
 1 ppm
Accuracy:
 ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and
50 % RH
C02
Range:
 0 to 5000 ppm
Display Resolution:

1 ppm
Accuracy:
 Warm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm

Calculated specifications
Dew point temperature
Range:
 -44 °C to 50 °C, (-47 °F to 122 °F)
Display Resolution:
 0.1 °C (0.1 °F)
Accuracy:
 ± 1 °C when temp: -20 °C to 50 °C RH: 40 % to 90 %
± 2 °C when temp: -20 °C to 50 °C RH: 20 % to 40 %
± 4 °C when RH: 10 % to 20 %
Wet bulb temperature
Range:
 -16 °C to 50 °C, (3 °F to 122 °F)
Display Resolution:
 0.1 °C, (0.1 °F)
Accuracy:
 ± 1.2 °C when RH: 20 % to 90 % temp: -20 °C to 60 °C
± 2.1 °C when RH: 10 % to 20 %
Volume flow rate (in a duct)
Range:
 0 to 3,965 M3/m, (0 to 140,000 cfm)
Display Resolution:
 0.001 M3/min, (1 cfm)
Accuracy:
 N/A: The volume flow calculation will be a simple average of the data points times the duct area
% outside air (based on temperature)
Range:
 0 to 100%
Display Resolution:
 0.1
% outside air (based on CO2)
Range:
 0 to 100 %
Display Resolution:
 0.1 % N/A


General specifications
Operating and storage temperature:
 -20 °C to 50 °C (-4 °F to 122 °F)
Humidity
 10 % to 90 % (non-condensing)
Altitude
 Up to 2000 m (6562 ft)
Shock and vibration
 MIL-PRF-28800F: Class 2
Multi-language interface
 English, French, Spanish, Portuguese and German
Battery
 Rechargeable Li-Ion (primary), three-AA (backup)
Data logging
 25,000 records (continuous), 99 records (discrete)
Warranty
 Two-years