FLUKE
– Máy đo lưu lượng không khí Fluke-975
Model:
Fluke 975
Hãng
sản xuất: FLUKE – MỸ 
Tính năng Máy đo lưu lượng không khí Fluke-975:
The Fluke 975 offers an
unparalleled featureset for HVAC and facilities technicians, helping them work
more quickly and accurately, with the ease of use and durability customers
expect from a Fluke meter.
 
  
  
- Simultaneously
       measures, logs, and displays temperature, humidity, CO2, and
       CO on a bright, backlit LCD display
 
- One-touch
       air flow and velocity with available probe*
 
- Wet
       bulb and dew point temperature
 
- % of
       outside air calculation
 
- CO2 and
       CO field calibration feature
 
- Self-test
       function at startup
 
- Auto-backlight
 
- Automatically
       compensates for barometric pressure changes
 
- Min/Max/Average
       on all measured and calculated readings
 
- Multi-language
       user interface
 
- Metric
       or standard units
 
- Audible
       and visual threshold alarms
 
- Extensive
       discrete or continuous data logging capacity, downloadable to PC via USB
       interface
 
- Keypad
       lock for security
 
- Included
       FlukeView Forms® software
 
 
 | 
 
Thông số kỹ thuật Máy
đo lưu lượng không khí Fluke-975:
 
  | 
   
Measured specifications 
 | 
 
  | 
   
Temperature 
 | 
  
  
   
    | 
     
Range: 
 | 
    
     
 -20 °C to 50 °C (-5 °F to 122 °F) 
 | 
    
    | 
     
Display resolution: 
 | 
    
     
 0.1 °C (0.1 °F) 
 | 
    
    | 
     
Accuracy: 
 | 
    
     
 ± 0.9 °C/± 1.62°F from 40 °C to 60 °C 
    ± 0.5 °C/± 1.00°F from 5 °C to 40 °C 
    ± 1.1 °C/± 1.98 °F from -20 °C to 5 °C 
 | 
    
 
 | 
 
  | 
   
Relative humidity 
 | 
  
  
   
    | 
     
Range: 
 | 
    
     
 10 % to 90 % RH, non-condensing 
 | 
    
    | 
     
Display Resolution: 
 | 
    
     
 1% 
 | 
    
    | 
     
Accuracy: 
 | 
    
     
 ± 2 % RH (10 % RH to 90 % RH) 
 | 
    
 
 | 
 
  | 
   
Air velocity 
 | 
  
  
   
    | 
     
Range: 
 | 
    
     
 50.0 fpm to 3000 fpm 
    0.25 m/sec to 15 m/sec 
 | 
    
    | 
     
Display Resolution: 
 | 
    
     
 1 fpm (0.005m/sec) 
 | 
    
    | 
     
Accuracy: 
 | 
    
     
 ±4 % or 4 fpm* 
    ±4 % or 0.02 m/sec* whichever is greater 
    *Accuracy specification only valid for velocity readings above 50 fpm. 
 | 
    
 
 | 
 
  | 
   
C0 
 | 
  
  
   
    | 
     
Range: 
 | 
    
     
 0 to 500 ppm 
 | 
    
    | 
     
Display Resolution: 
 | 
    
     
 1 ppm 
 | 
    
    | 
     
Accuracy: 
 | 
    
     
 ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and 
    50 % RH 
 | 
    
 
 | 
 
  | 
   
C02 
 | 
  
  
   
    | 
     
Range: 
 | 
    
     
 0 to 5000 ppm 
 | 
    
    | 
     
Display Resolution: 
 | 
    
     
 
    1 ppm 
 | 
    
    | 
     
Accuracy: 
 | 
    
     
 Warm up time 1 min (5 minutes for full specification) 2.75% + 75
    ppm 
 | 
    
 
 | 
 
 
 
  | 
   
Calculated specifications 
 | 
 
  | 
   
Dew point temperature 
 | 
  
  
   
    | 
     
Range: 
 | 
    
     
 -44 °C to 50 °C, (-47 °F to 122 °F) 
 | 
    
    | 
     
Display Resolution: 
 | 
    
     
 0.1 °C (0.1 °F) 
 | 
    
    | 
     
Accuracy: 
 | 
    
     
 ± 1 °C when temp: -20 °C to 50 °C RH: 40 % to 90 % 
    ± 2 °C when temp: -20 °C to 50 °C RH: 20 % to 40 % 
    ± 4 °C when RH: 10 % to 20 % 
 | 
    
 
 | 
 
  | 
   
Wet bulb temperature 
 | 
  
  
   
    | 
     
Range: 
 | 
    
     
 -16 °C to 50 °C, (3 °F to 122 °F) 
 | 
    
    | 
     
Display Resolution: 
 | 
    
     
 0.1 °C, (0.1 °F) 
 | 
    
    | 
     
Accuracy: 
 | 
    
     
 ± 1.2 °C when RH: 20 % to 90 % temp: -20 °C to 60 °C 
    ± 2.1 °C when RH: 10 % to 20 % 
 | 
    
 
 | 
 
  | 
   
Volume flow rate (in a duct) 
 | 
  
  
   
    | 
     
Range: 
 | 
    
     
 0 to 3,965 M3/m, (0 to 140,000 cfm) 
 | 
    
    | 
     
Display Resolution: 
 | 
    
     
 0.001 M3/min, (1 cfm) 
 | 
    
    | 
     
Accuracy: 
 | 
    
     
 N/A: The volume flow calculation will be a simple average of the
    data points times the duct area 
 | 
    
 
 | 
 
  | 
   
% outside air (based on temperature) 
 | 
  
  
   
    | 
     
Range: 
 | 
    
     
 0 to 100% 
 | 
    
    | 
     
Display Resolution: 
 | 
    
     
 0.1 
 | 
    
 
 | 
 
  | 
   
% outside air (based on CO2) 
 | 
  
  
   
    | 
     
Range: 
 | 
    
     
 0 to 100 % 
 | 
    
    | 
     
Display Resolution: 
 | 
    
     
 0.1 % N/A 
 | 
    
 
 | 
 
 
 
  | 
   
General specifications 
 | 
 
  | 
   
Operating and storage temperature: 
 | 
  
  
   
     | 
    
     
 -20 °C to 50 °C (-4 °F to 122 °F) 
 | 
    
 
 | 
 
  | 
   
Humidity 
 | 
  
  
   
     | 
    
     
 10 % to 90 % (non-condensing) 
 | 
    
 
 | 
 
  | 
   
Altitude 
 | 
  
  
 | 
 
  | 
   
Shock and vibration 
 | 
  
  
 | 
 
  | 
   
Multi-language interface 
 | 
  
  
   
     | 
    
     
 English, French, Spanish, Portuguese and German 
 | 
    
 
 | 
 
  | 
   
Battery 
 | 
  
  
   
     | 
    
     
 Rechargeable Li-Ion (primary), three-AA (backup) 
 | 
    
 
 | 
 
  | 
   
Data logging 
 | 
  
  
   
     | 
    
     
 25,000 records (continuous), 99 records (discrete) 
 | 
    
 
 | 
 
  | 
   
Warranty 
 | 
  
  
 | 
 
 
 
Không có nhận xét nào: