                                Kết quả hình ảnh cho Fluke 1587/1577  FLUKE
Tính năng Thiết bị đo điện trở cách điện Fluke 1587/1577:
Consult the features included on the two new insulation multimeters in the comparison chart below to help select the best tool for your application:
Feature
1587
1577
Insulation test voltages 50V, 100V, 250V, 500V, 1000V

Insulation test voltages 500V, 1000V

Insulation test: 0.01 MΩ to 2.0 GΩ

Insulation test: 0.1 MΩ to 600 MΩ

Auto discharge of capacitive voltage
Insulation test smoothing reading

Frequency

Capacitance

Diode test

Temperature

Min/Max

Low pass filter (for work on VSD's)

AC/DC Voltage
DC millivolts
AC/DC milliamps
Resistance (0.1 Ω to 50 MΩ)
Continuity
Three-year warranty
Remote probe, test leads, alligator clips
K-type thermocouple

Rugged, utility hard case
Auto power off to save battery power
True-rms
Large display with backlight
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
CAT III 1000V, CAT IV 600V measurement category
Accepts optional Fluke TPAKTM magnetic hanging system to free your hands for other work

Thông số kỹ thuật Thiết bị đo điện trở cách điện Fluke 1587/1577:
Specifications
Voltage DC
Maximum Voltage:
 1000 V
Accuracy:
 1577: ±(0.2%+2)
 1587: ±(0.09%+2)
Maximum Resolution:
 0.001V
Voltage AC
Maximum Voltage:
 1000 V
Accuracy:
 1577: ±(2%+3)
 1587: ±(2%+3)
AC Bandwidth:
 1587: 5kHz*
 *with low pass filter; 3db @ 800 Hz
Maximum Resolution:
 0.1 mV
Current DC
Maximum Amps:
 400mA
Amps Accuracy:
 1577: ±(1.0%+2)
 1587: ±(0.2%+2)
Maximum Resolution:
 0.01 mA
Current AC
Maximum Amps:
 400mA
Amps Accuracy:
 1577: ±(2.0%+2)*
 1587: ±(1.5%+2)*
 * 1kHz bandwidth
Maximum Resolution:
 0.01 mA
Resistance
Maximum Resistance:
 50 MΩ
Accuracy:
 1577: ±(1.2%+2)
 1587: ±(0.9%+2)
Maximum Resolution:
 0.1Ω
Capacitance(1587 only)
Maximum Capacitance:
 9,999 µF
Accuracy:
 ±(1.2%+2)
Maximum Resolution:
 1 nF
Frequency (1587 only)
Maximum Frequency:
 100 kHz
Accuracy:
 ±(0.1%+1)
Maximum Resolution:
 0.01 Hz
Temperature Measurement (1587 only)
 -40.0 °C to 537 °C
 -40.0 °F to 998 °F
 excluding probe
Diode Test (1587 only)
Range:
 6 V
Resolution:
 1 mV
Accuracy:
 ±(2 % + 1)

Insulation Test
Minimum Test Current @ 1kΩ/V:
 1mA
Test Voltages:
1577:
 500, 1000 V
1587:
 50, 100, 250, 500, 1000 V
Maximum Resistance per Test Voltage:
50V:

100V:

250V:

500V:

1000V:
 1577: 600 MΩ
 1587: 2 GΩ
Maximum Resolution per Test Voltage:
50V:
 0.01 MΩ
100V:
 0.01 MΩ
250V:
 0.1 MΩ
500V:
 0.1 MΩ
1000V:
 0.1 MΩ
Accuracy per Test Voltage:
50V:
 ±(3 % + 5)
100V:
 ±(3 % + 5)
250V:
 ±(1.5 % + 5)
500V:
 1577: ±(2.0 % + 5)
 1587: ±(1.5 % + 5)
1000V:
 1577: ±(2.0 % + 5)
 1587: ±(1.5 % + 5) to 600 MΩ, ±(10 % + 3) above 600 MΩ

Environmental Specifications
Operating temperature
 –20 °C to +55 °C
Storage temperature
 -40°C to +60°C
Humidity (Without Condensation)
 0% - 95% (10 °C – 30 °C)
 0% - 75% (30 °C – 40 °C)
 0% - 40% (40 °C – 55 °C)
Operating Altitude
 2000 m

Safety Specifications
Overvoltage category
 Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
Agency Approvals
 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V

Mechanical & General Specifications
Size
 203 x 100 x 50 mm (with holster)
Weight
 624 g
Warranty
 3 years
Battery life Alkaline
Meter use:
 1000 hours
Insulation test use:
 Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
IP Rating
 IP40