FLUKE – Máy hiện sóng Fluke 190 series II
Model: Fluke 190 series II
Hãng sản xuất: FLUKE – MỸ
Tham khảo: http://www.fluke.com/fluke/vnen/portable-oscilloscopes/fluke-190-series-ii-scopemeter.htm?PID=70366
Tính năng Máy hiện sóng Fluke 190 series II:
See More, Fix More with the Two and Four-Channel CAT IV Rated Fluke ScopeMeter 190 Series II
The Fluke ScopeMeter 190 Series II combines the highest safety ratings and rugged portability with the high performance of a bench oscilloscope. Designed for plant maintenance engineers and technicians, these tough ScopeMeter test tools go into harsh, dirty, and hazardous industrial conditions to test everything from microelectronics to power electronics applications.
The 190 Series II is the one test tool you will reach for to tackle just about any troubleshooting task. They include a multimeter, TrendPlot™ and ScopeRecord™ roll paperless recorder modes and hands free operation with Connect-and-View™ triggering, and much more:
- Two or four electrically isolated inputs
- CAT III 1000V / CAT IV 600V safety rated
- Choose from 60 MHz, 100MHz, 200MHz or 500MHz bandwidth models
- Fast sampling rate, up to 5GS/s with up to 200 ps resolution (Depending on model and channels used)
- Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details
- Dedicated 5000 Count digital multimeter in two-channel models
- Four meter measurements via scope BNC inputs in four-channel models
- Connect-and-View™ continuous auto-trigger, single shot, pulse width, and video triggering
- ScopeRecord roll mode, capture waveform sample data for up to 48 hours
- TrendPlot, trend measurement readings for up to 22 days
- Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
- IP-51 rated for dust and drip proof to withstand harsh environments
- Isolated USB ports for memory devices and PC connectivity
- Li-Ion battery for extended operating timespan:
- 190-X04, four-channel models up to 7 hour (BP291 included standard)
- 190-X02, two-channel models up to 4 hours (BP290 included standard) or up to 8 hour with optional BP291
- Charge spare battery using optional external battery charger EBC290
- Easy-access battery door to make it easy to swap batteries
- A handy slot to tether and lock down the oscilloscope while unattended using a standard Kensington® lock
Gain Four Times the Diagnostic Power Plus CAT IV Safety Rating
The Fluke ScopeMeter 190 Series II portable scopes are double-insulated two and four-channel floating oscilloscopes, safety rated for measurements in CAT III 1000V/CAT IV 600V environments.
Tính năng Máy hiện sóng Fluke 190 series II:
Specifications
| |
Bandwidth
|
Fluke 190-504: 500 MHzFluke 190-204: 200 MHzFluke 190-202: 200 MHzFluke 190-104: 100 MHzFluke 190-102: 100 MHzFluke 190-062: 60 MHz
|
Number of channels
|
Fluke 190-504: 500 MHz: 4 channelsFluke 190-204: 200 MHz: 4 channelsFluke 190-202: 200 MHz: 2 channelsFluke 190-104: 100 MHz: 4 channelsFluke 190-102: 100 MHz: 2 channelsFluke 190-062: 60 MHz: 2 channels
|
Real-time sample rate
|
Fluke 190-504: 5 GS/sFluke 190-204: 2.5 GS/sFluke 190-202: 2.5 GS/sFluke 190-104: 1.25 GS/sFluke 190-102: 1.25 GS/sFluke 190-062: 625 MS/s
|
Inputs
|
Fluke 190-X04: 4x BNC input for scope and meter measurementsFluke 190-X02: 2x BNC input plus 1x DMM input
|
Independently floating isolated inputs
|
Up to 1000 V CAT III/600 V CAT IV between inputs, references and ground
|
Timebase range
|
1 ns/div to 4s/div (190-504, 500 MHz model)
2 ns/div to 4s/div (190-20X, 200 MHz models) 5 ns/div to 4s/div (190-10X, 100 MHz models) 10 ns/div to 4s/div (190-062, 60 MHz model) |
Input sensitivity
|
2 mV-100 V/div plus variable attentuation
|
Trigger types
|
Connect-and-View™, Free Run, Single Shot, Edge, Delay, Dual Slope, Video, Video Line, Selectable pulse width, N-Cycle
|
Trigger source
|
Fluke 190-X02: 2x BNC input or external via DMM inputFluke 190-X04: 4x BNC input
|
Glitch capture
|
8 ns
|
Scope measurements
|
Cursor: 7Automatic: 30
|
Maximum record length
|
ScopeRecord mode: 30,000 pts per inputScope mode: 10,000 pts per input
|
Persistence
|
Digital persistence giving analog oscilloscope-like waveform decay
|
Waveform compare
|
Waveform reference with automatic Pass/Fail testing
|
DMM Specifications (Two-Channel Models)
| |
Meter inputs
(also used as External Trigger Input for the Oscilloscope Mode) |
4 mm banana inputs, fully isolated from scope inputs and from scope ground
|
Maximum resolution
|
5000 counts
|
Measurements
|
Vdc, Vac rms, Vac+dc rms, Resistance, Continuity, Diode Test, Current (through clamp or shunt), Temperature ºC or ºF (using optional converter)
|
Memory locations
|
Screen + Setup: 30 Waveform memories plus 10 recording memories plus 9 screencopy memories.
|
Display
|
153 mm full color LCD with fast update rate
|
Environmental Specifications
| |
Operating temperature
|
0ºC to 40ºC Including Batteries
0ºC to 50ºC Excluding Batteries |
Storage temperature
|
-20°C to +60°C
|
Operating altitude
|
Up to 2,000 m (6666 ft) for CAT IV 600 V/ CAT III 1,000 V
Up to 3,000 m (10,000 ft) for CAT III 600 V/ CAT II 1,000 V |
Safety Specifications
| |
Electrical safety
|
1,000V CAT III/600V CAT IV (EN61010-1)
|
Mechanical and General Specifications
| |
Size
|
270 x 190 x 70 mm
|
Weight
|
2.2 kg
|
Warranty
|
Three-years on main instrument
|
Li-Ion battery
|
Fluke 190-XX2: BP290 (2400mAh)Fluke 190-XX4: BP291 (4800mAh)
|