FLUKE - Ampe kìm Fluke 902 True-rms HVAC
Model:
Fluke 902 True-rms HVAC
Hãng
sản xuất: FLUKE – MỸ
Tính năng Ampe kìm Fluke 902 True-rms HVAC:
The new Fluke 902 True
RMS HVAC Clamp Meter provides the accuracy, reliability and ruggedness that
define Fluke test tools. It is designed for HVAC technicians for the systems
they service and install daily. With True RMS technology and a CAT III 600V
rating, HVAC technicians can troubleshoot and maintain HVAC equipment safely
and with confidence in the results.
Use the Fluke 902 to get
more done:
- Capture
flue gas temperatures
- Conduct
flame rod testing
- Measure
start and run motor capacitors
- Measure
supply side current and voltage as well as load side current and voltage
- Measure
current and voltage phase balance on 3 phase systems
- Troubleshoot
compressor electrical motor faults
- Measure
performance of variable frequency drives
|
Features:
- Designed
for HVAC applications with capacitance, DC Current (µA), and temperature
measurements
- Small
body and jaws fit perfectly in your hand and into tight places
- Handy
'Display Hold' button keeps measurements on the display
- Meter
controls are positioned so current measurements can be done with one
hand (index finger on clamp opening lever and thumb on rotary switch)
- Large,
backlit display is easy-to-see in less than ideal conditions
- Auto
shut-off maximizes battery life so the meter works when you need it
- Three
year warranty
|
Thông số kỹ thuật Ampe kìm Fluke 902 True-rms HVAC:
Voltage DC
|
Range
|
0 – 600.0 V
|
Accuracy
|
1% ± 5 counts
|
|
Voltage AC (True RMS)
|
Range
|
0 – 600.0 V
|
Accuracy
|
1% ± 5 counts (50/60 Hz)
|
|
Current AC (True RMS)
|
Range
|
0 – 600.0 A
|
Accuracy
|
2.0% ± 5 counts (50/60 Hz)
|
|
Current DC
|
Range
|
0 - 200.0 µA
|
Accuracy
|
1.0% ± 5 counts
|
|
Resistance
|
Range
|
0 – 9999 Ω
|
Accuracy
|
1.5% ± 5 counts
|
|
Continuity
|
|
Temperature*
(Type K Thermocouple)
|
Range
|
-10 degree C to 400 degree C (-14 degree F to 752 degree F)
|
Accuracy
|
+/- 1.0% + 0.8 degree C (+/- 1.0% + 1.5 degree F) typical
|
Range
|
-40 degree C to -10 degree C (-40 degree F to -14 degree F)
|
Accuracy
|
+/- 5.0% + 1.5 degree C (+/- 5.0% + 3.3 degree F) typical
|
|
Capacitance
|
Range
|
1-1000 µF
|
Accuracy
|
1.9% ± 2 counts
|
|
* Error does not include Type K Thermocouple errors
Mechanical & General Specifications
|
Weight
|
|
Dimensions
|
|
10.75” x 4.25” x 2.44” (27.3 cm x 10.8 cm x 6.2 cm)
|
|
Battery type
|
|
(2) AA Alkaline Batteries
|
|